Changing the door hinge
The door hinge should only be changed by trained specialists. Two
people are required for the modification.
1. Remove the cover plate.
Important
The door must be held securely by
a second person.
2. Unscrew the bearing bolt from
the upper hinge bracket. Subse-
quently, remove the door.
3. Set the clamping plate on the
opposite side.
4. Loosen front pressure
plates
and pull back to
remove
.
5. Unscrew the door handle
and assemble it again on
the opposite side.
20
6. Set the hinges and cover plates on
the opposite side.
7. Unscrew the screw using the
wrench provided.
8. Unscrew the hinge bracket.
9. Transfer the cover to the opposite
side.
10. Remove the cover plate, then
turn it 180° and reinsert it on
the opposite side.
11. Screw on the hinge bracket.
12. Tighten the screw.
Attention
the door must be held by a
second person!
13. Place the door on the latch
and guide it to the upper
edge of the hinge.
14. Insert the bearing pin. Align
door laterally and tighten
bearing bolts.
Replace the cover plate.
21