Note that for transport of the hose reel it is advisable to maintain sufficient tension on the
hose reel to arrest any rotation of the hose reel spool caused by motion of the unit.
Mode 3 – Powered Unload
The UNLOAD mode is achieved by the mode toggle switch is in the UNLOAD position
and the belt is sufficiently tightened to transmit power from the motor/gearbox to the hose
reel spool.
The foot switch is momentary and will only operate when it is depressed.
Mode 4 – Cold Starting
It is advisable that when beginning operation below 18
temporarily loosened far enough that motor rotation will not cause spool rotation and that
the motor be powered for a minimum of 5 minutes. This will allow the oil in the gearbox to
warm up and to allow smooth low-temperature operation.
Following system warm-up re-tension the belt and begin your desired operation.

Mechanical Drive Components

Access to the internal mechanical drive components (Figure 2-2) is
through the access door. This door must be removed.

Electric Motor

No regular maintenance is required.
Low temperature automatic reset thermal protector.
Totally enclosed and fully gasketed construction for dirty
environments.
Make sure that, during operation or storage, the motor is not
in prolonged contact with moisture.
Refer to the chart "Table 1- Electric motor features & data",
below for motor data.
Table 1: Electric Motor Features & Data
PRODUCT FEATURE - ENCLOSED HIGH TORQUE PMDC MOTOR
Model Number:
MPTM-001-1L18
Power:
1 HP
1800 RPM
ω:
Voltage:
90VDC
Frame:
NEMA 56C
Mounting:
C-FACE
Setup/Operation
Weight:
29 Lbs
Torque:
2.92 Ft*Lbs.
Housing Rating:
TEFC
Insulation Class:
F
Output Shaft:
5/8''
Service Factor:
1.0
o
o
F (-8
C) that the belt tension be
Figure 2-2: Electric Motor