4. Remove the Titanium apatite photocatalytic filter roll.
5. Remove the opposing pole plates (two).
• Push and expand the knobs on the outside and raise up the knob
side of the opposing pole plates and then remove them on the
outside.
Knob
CAUTION
• When cleaning be careful not to cut your hands on the opposing
pole plates. (Wearing rubber gloves is safer.)
ATTENTION
• The ionizing line is located
at the rear of the opposing
pole plates.
When removing the plates,
be careful not to catch and
cut the ionizing line.
6. Clean the opposing pole plates.
• After using a vacuum cleaner to remove any dust, clean with
water.
• If very dirty, clean using a neutral household cleaner or after
applying the cleaner, rub with a rag or soft brush and sufficiently
clean with water until no cleaning agent is left and then dry in the
shade.
ATTENTION
• Do not use water to clean the plasma ionizer (resin part).
• After cleaning, wipe with a cloth until none is remaining.
• Do not use acidic or alkaline cleaners. Rust may occur.
Neutral
cleaners
Knob
Opposing pole plates (2)
Titanium apatite photocatalytic filter roll
Opposing pole plate
Ionizing line
Acidic
Alkaline
cleaners
cleaners
7. Clean the plasma ionizer.
• Use water to slightly moisten the ionizing line and surrounding
resin parts and then use a tissue to gently wipe along the ionizing
line.
CAUTION
• When cleaning be careful not to cut your hands on the ionizing line.
(Wearing rubber gloves is safer.)
• Be careful not to snag or cut the ionizing line. If the ionizing line is
cut, request the Daikin dealer to replace it.
If the unit is operated with the ionizing line cut, there will be no dust
collection. The "Clean sign" may also flash.
• After cleaning, thoroughly dry the plasma ionizer. If the unit is oper-
ated before it is dry, the "Clean indicator" may also flash.
8. Set the opposing pole plates in the plasma ionizer
(resin part).
(1) Securely insert the opposing pole plates into the hooks (two at
center) of the plasma ionizer.
(2) While pressing and expanding the knobs (one on each side) of
the plasma ionizer towards the outside, securely insert the
opposing pole plates.
(1) Hook
(2) Knob
Plasma ionizer
(Resin part)
ATTENTION
• When removing the opposing pole plates, be careful not to catch
and cut the ionizing line.
9. Install the Titanium apatite photocatalytic filter roll in its
original position.
• Refer to procedure 7 on Page 9.
10. Install the plasma ionizer in its original configuration.
• Refer to procedure 8 on Page 9.
11. Install the front panel to its original position.
• Refer to procedure 5 on Page 8.
Ionizing line
(2) Knob
Opposing pole
plate
10