3M W-2806/07006 User Instructions - Page 3
Browse online or download pdf User Instructions for Monitor 3M W-2806/07006. 3M W-2806/07006 19 pages. Compressed air filter and regulator panel
Also for 3M W-2806/07006: General Operation And Parts Instructions (2 pages)
GENERAL SAFETY INFORMATION
Intended Use
The 3M
TM
Carbon Monoxide (CO) Monitor and the 3M
Monitor Kit are designed to provide continuous, direct read CO monitoring for compressed
air used with supplied air respirators.
List of Warnings and Cautions within these User Instructions
• These products are designed for carbon monoxide monitoring. Misuse may result in
sickness or death. For proper use, see supervisor or User Instructions, or call 3M in U.S.A.,
1-800-243-4630. In Canada, call Technical Service at 1-800-267-4414.
• The impedance of any connected load device at the REM ALARM (remote alarm) jack must
be greater or equal to 12 ohms, when operating from internal batteries or AC adapter. Failure
to do so may damage the carbon monoxide monitor and result in sickness or death.
• The intrinsic safety of the carbon monoxide monitor is voided when remote alarm is used.
• The intrinsic safety of the carbon monoxide monitor is voided when the 110-120 volt AC
adapter is used.
• Your employer must provide breathing air that meets at least the requirements of the
specification for Grade D breathing air, as described in the Compressed Gas Association
Commodity Specification G-7.1-1997 in the United States. In Canada refer to CSA standard
Z180.1, for the quality of the compressed breathing air. Failure to do so may result in
sickness or death.
• Use of equipment described in these User Instructions must be in accordance with applicable
health and safety standards, or pursuant to the recommendations of an industrial hygienist.
• Each person using this equipment must read and understand the information in these User
Instructions. Use of this equipment by untrained or unqualified persons, or use that is not
in accordance with these User Instructions, may adversely affect product performance and
result in sickness or death.
CAUTION:
•
Observe proper polarity when inserting batteries. Polarity is marked on the inside of the drawers.
•
The sensor in the carbon monoxide monitor contains a small amount of sulfuric acid. Always
wash hands thoroughly after handling sensor cell. Sulfuric acid is poisonous and can cause
severe burns. Do not allow acid to contact skin or eyes. If eyes are exposed to acid, flush
thoroughly and seek immediate medical attention.
W WARNING
2
TM
Retrofit Carbon Monoxide (CO)