DSC PK5500 Installation Instructions Manual - Page 2
Browse online or download pdf Installation Instructions Manual for Security System DSC PK5500. DSC PK5500 16 pages. Power series
Also for DSC PK5500: Instruction Manual (20 pages), Installation Instructions Manual (9 pages), Installation Instructions Manual (8 pages)
The PK5500 keypad can be used on security systems with up to 64
zones. These keypads are compatible with the latest version of the foll-
lowing DSC security systems:
•PC580
•PC585
•PC1555MX
•PC1616
•PC1832
•PC1864
•PC5008
•PC5010
•PC5015
•PC5020
Specifications
• Temperature range: -10°C to +55°C (14°F to 131°F)
• Humidity (MAX): 93% R.H., non-condensing
• Plastic enclosure protection degree: IP30, IK04
• Voltage rating: 12V
nominal
DC
• Connects to control panel via 4-wire Keybus
• 1 keypad zone input/PGM output*
• PK5500 Current Draw: 50mA (standby)/125mA (maximum)
• Wall mount tamper
• 5 programmable function keys
• Ready (Green LED), Armed (Red LED), Trouble (Yellow LED), A C (Green LED)
• Low temperature sensor: Alarm 6°C (43°F)/Restore 9°C (48°F)
NOTE: * Zone not to be programmed as Fire type or 24h type.
Unpacking
The Power keypad package includes the following parts:
•One Power keypad
•Keypad inner door labels
•Four mounting screws
•1 tamper switch
•2 end-of-line resistors
•Installation Instructions
Mounting
Mount the keypad where it is accessible to designated points of entry
and exit. Once you have selected a dry and secure location, perform
the following steps to mount the keypad.
Disassemble Keypad
1. Insert a flat head screwdriver into the provided slot (first of two).
2. Move screwdriver toward the back plastic and lift as in the following
diagram. This will unhook one side of the front plastic.
3. Repeat step # 1 and 2 on the second provided slot to disconnect
the front plastic and allow access for wiring.
•PC1565
•PC5005
•PC5016
Mount and Wire Keypad
Knock Out
Wiring Slot
Knock Out
Hooks
1.
3.
3
1
2
Knock Out
Tamper
2.
Swing
Hooks
to engage
4.
Tamper
Press to Snap
1. Secure Keypad to wall using mounting holes. Use all 4 screws provided
unless mounting on a single gang box.
2. Place keypad into hooks on the backplate and swing down to engage.
3. Run wire through wiring slot or knockouts. Connect Keybus and PGM/Zone
wiring to keypad. Place tamper switch into tamper hole on backplate.
4. Remove keypad from hooks. Place keypad into backplate, ensure the wire
is pushed back into the wall as much as possible. Route the wire inside
the keypad ensuring high components are avoided. Snap the front assem-
bly closed, ensuring there is no pressure to the keypad from the wire
below.
NOTE: If any tension found between the front keypad assembly
and wiring, please open the keypad reroute the wire and close
again. Repeat these steps until the keypad is closed properly.
Wiring
1. Before wiring the unit, ensure that all power (AC transformer and battery)
is disconnected from the control panel.
2. Connect the four Keybus wires from
the control panel (red, black, yellow
and green) to the keypad terminals.
Refer to diagram.
3. If programmed as an input, you can
connect a device - such as a door
contact - to the "P/Z" terminal of the
To zone or
keypad. This eliminates the need to
PGM output
run wires back to the control panel for
the device. To connect the zone, run one wire from the device to the "P/Z"
terminal and the other wire from the device to the B (black) terminal. For
powered devices, run the red wire to the R (positive) terminal and the
black wire to the B (negative) terminal. When using end of line supervi-
sion, connect the zone according to one of the configurations outlined in
your system's Installation Manual.
4. If the P/Z terminal is programmed as an output, the output follows the
PGM programmed in Section [080]. A small relay, buzzer or other DC
operated device may be connected between the positive supply voltage
and the P/Z terminal (maximum load is 50mA).
Applying Power
Once all wiring is complete, and the equipment is secured to the building
structure with at least two screws apply power to the control panel:
1. Connect the battery leads to the battery.
2. Connect the AC transformer.
For more information on control panel power specifications, see the control
panel Installation Manual.
PK5500
RED
BLK
YEL
GRN