3.
INTRODUCTION TO LEADING EDGE SELF RETRACTABLE LIFELINE: Each SRL in this range is constructed in such a way that if
subjected to contact with a sharp edge in the event of a fall from a roof/ terrace etc, the retracted lanyard remains intact, while arresting
the fall immediately.
Conforms for the vertical usage as per ANSI Z 359.14-2014 and Horizontal usage as per ANSI Z 359.14-2014 SRL-LE
Ÿ Connect the end of Lifeline, adjacent to Energy Absorber, to the dorsal attachment of the body support.
Ÿ LE range of SRL's are tested and suitable to be used on edges having radii not greater than 0.005".
4.
POSSIBLE USAGE FOR ELECTRON RETRACTABLE FALL ARRESTER:
* It can be used where the Anchorage point is available at foot Level also. (Refer g 01)
How to Use: Follow below steps to use this equipment as single or double Lanyard. (Refer
g 02)
STEP 1: Connect the swivel eye of the retractable fall arrester to the dorsal attachment of
the full body harness with the help of special connector PN 170 and PN 169 & ensure the
connector is locked.
STEP 2: Now connect the snap/scaffold hook at the termination end of the device to the
structure and ensure that it is locked. You are now safe to move in normal speed. In the
event of a fall, the Retractable Fall Arrester locks & also minimizes the impact forces on the
body of user.
Similarly, it can be used where the anchorage point is available at foot level by just
connecting the swivel eye of the retractable to the anchorage point and the hook at
termination to the dorsal attachment of harness.
3.
HOW TO USE ELECTRON AS TIE-BACK: SAFE KEEPER Electron with Tie-back hook should be used with the SRL casing attached to the
Dorsal D-ring of the full body harness, and the extended webbing (with a sheath) wrapped around the anchorage structure, and the Tie-
back hook secured around the webbing.
WARNING:
NEVER use Electron Tie Back SRL in Leading Edge (LE) applications.
Ÿ
ALWAYS avoid lifeline contact with sharp or abrasive edges and surfaces.
Ÿ
For Tie – Back application, snap hook must only be attached to webbing below shock pack. NEVER attach snap hook
Ÿ
between housing and shock pack.
No Free Fall is allowed
Ÿ
LIST OF RETRIEVAL TYPE LEADING EDGE FALL ARREST SRL's
Lifeline Material and Size
7X19 Galvanized Steel cable (
7X19 Galvanized Steel cable (
7X19 Galvanized Steel cable (
7X19 Galvanized Steel cable (
LIST OF RETRIEVAL TYPE RETRACTABLE FALL ARREST SRL's
Lifeline Material
and Size
7X19 Galvanized Steel
cable (3/16" dia)
7/32"
dia)
7/32"
dia)
7/32"
dia)
7/32"
dia)
Maximum
Lifeline
Arresting
Length
Force
60 ft
1800 lbs
(18 m)
2
Lifeline Length
18 ft (5.48 m)
20 ft (6.09 m)
25 ft (7.62 m)
30 ft (9.14 m)
Maximum
Arrest
ANSI Z359.14
Distance
54 inches
(1372 mm)
Weight
7.5 lbs
8.9 lbs
9.0 lbs
15.19 lbs
Comply
Class
B
Fig 01
Fig 02