DAITEM SH601AU Installation Manual - Page 14

Browse online or download pdf Installation Manual for Security System DAITEM SH601AU. DAITEM SH601AU 20 pages. Alarm pendant

7. Testing operation and radio coverage in test mode

IMPORTANT: Whatever the command sent by the sliding part or push-button:
• the advantage of the test mode is being able to test the pendant without reducing the radio range and:
- with sounding that lasts a shorter time: control panel (3 s.), siren (5 s.)
- without triggering telephone transmission,
• the siren's sounding power can cause hearing disorders and the necessary precautions must therefore be taken
during testing.
1. Switch the control panel (or dialler) to test mode:
installer code
2. Test operation:
Each command sent when the push-button is pressed for
more than 2 s (red or green flashing) is preceded by a "battery
status test" which briefly causes the LED to light up red.
• Press the push-button for 2 seconds (or pull on the sliding
part), the pendant LED flashes for roughly two seconds
before going out.
If the sliding part remains open, the message is re-transmitted
every 15 min.
• Use the table opposite to check the control panel response.
The dialler, in test mode, responds with a sharp beep and
does not trigger transmission whatever the command sent by
the pendant.
Command
description
"beep, test mode"
Alarm
Silent Alarm
(factory setting)
Local call
Fire alarm (1)
Door bell (1)
Audible signal (1)
(1) "Comfort" type command (green). Only possible
14
Control panel response
in test mode
sounding: 3 s.
"beep, alarm, command
n°"
"beep, emergency call,
command n°"
"beep, fire alarm,
command n°"
"ding, dong, command n°"
"beep, beep, beep, beep"
with push-button (see chapter on "Advanced
programming").