DAITEM 175-21X Installation Manual - Page 4
Browse online or download pdf Installation Manual for Security Sensors DAITEM 175-21X. DAITEM 175-21X 8 pages. Infared motion detector
Also for DAITEM 175-21X: Installation Manual (18 pages)
4. Configuration
IMPORTANT: The casing must be open when configuring the detector.
• Detection parameter selection:
Choice
Parameter
of function
n°
Detection sensitivity
1
Alarm level
4
Freeze detection
7
setting
• Follow the configuration sequence described below:
about 10 sec.
To start the sequence
Press 1, 4 or 7 times
press and hold the
button until the LED
required parameter
indicator lamp goes out
Configuration example: setting the detector for an alarm level when a full prealert is triggered: Parameter n° 4, Parameter
value 2.
Start
Press 4 times to select
Checking configuration: check the alarm level by selecting the Parameter N° and checking the number of corresponding
flashes.
Start
Press 4 times to select
Parameter Technical data
value
1
1
st
edge triggering: not recommended for detector 171-21X/175-21X
2
2
nd
edge triggering (factory setting):
recommended for interior using detector 171-21X/175-21X
1
Intrusion (factory setting)
2
Prealert
3
Deterrence
4
Warning
1
Disabled (factory setting)
3
Enabled
about
1, 4 or 7
5 sec.
Press and hold
depending on the
until the LED
indicator lamp
number
briefly goes out
4
Press once to
the alarm level
accept selection
4
Press once to
the alarm level
accept selection
1 to 4
about 10 sec.
Press 1 to 4 times
To end the sequence
depending on the
press and hold the button
required parameter
until the LED indicator
value
lamp goes out
2
Press 2 times
Press and hold until the
to select
LED goes out to finish
the prealert level
End
4
about 2 sec.
LED indicator
lamp lit =
correct
configuration
2
2 flashes confirm
that the device is set
for a prealert