DSC PowerSeries PC1616 Installation Manual - Page 12

Browse online or download pdf Installation Manual for Security System DSC PowerSeries PC1616. DSC PowerSeries PC1616 17 pages. System enhancement module
Also for DSC PowerSeries PC1616: Installation Manual (13 pages), Quick Manual (4 pages), Installation Manual (20 pages), Manual (18 pages)

DSC PowerSeries PC1616 Installation Manual
[310]-[311] Partition Identifier Codes
Enter a 6 digit Maintenance Code
[310 System Acct. Code
I___II___II___II___II___II___I
[311] Partition 1 Acct. Code
I___II___II___II___I
[350] – Communicator Format Options
This section determines the communication format used for central
station reporting. From the chart listed below program the 2-digit num-
ber for the desired format for the first and second telephone number
Def
Enter 2 digits From Chart Below
04
I___II___I
NOTE: 3rd Phone Number follows the format of the
04
I___II___I
01 20BPS, 1400 Hz Handshake
02 20BPS, 2300 Hz Handshake
03 DTMF Contact ID
04 SIA FSK
05 Pager
06 Residential Dial
[367] – Opening/Closing Call Direction Options
The first toggle option in this section is used to enable/disable opening/
closing reporting for partition 1. To enable opening/closing reporting
turn option [1] ON. Configure the options as required and press [#] to
exit
.
Opt
Default
Description
1
I__I
ON
1st Telephone Number
OFF
Disabled
2
I__I
ON
2nd Telephone Number
OFF
Disabled
5
I__I
ON
Alternate Communicator
OFF
Disabled
[377] Communication Variables
NOTE: For UL Installations, the Entry Delay plus the Communications
Delay must not exceed 60 seconds.
Def
Enter 3 digits as indicated below
003 I___II___II___I
Swinger Shutdown
(Alarms and Rest.
003 I___II___II___I
Swinger Shutdown
(Tamper and Rest.
003 I___II___II___I
Swinger Shutdown
(Maint. and Rest.
000 I___II___II___I
Communication Delay
030 I___II___II___I
AC Failure Comm Delay
010 I___II___II___I
TLM Trouble Delay
030 I___II___II___I
Test Transmission Cycle
(land line)
030 I___II___II___I
Not Used
007 I___II___II___I
Zone low Battery
Transmission Delay
030 I___II___II___I
Delinquency Transmis-
sion Cycle
000 I___II___II___I
Communications
Cancelled Window
NOTE: Option 1 is defaulted to 001 for CP-01 Installations
Option 4 is defaulted to 030 for CP-01 Installations
Option 11 is defaulted to 005 for CP-01 Installations
1st Phone Number
07 10BPS, 1400 Hz Handshake
08 10BPS, 2300 Hz Handshake
09 Private Line
10 Scantronics 4-8-1 Fast Slo
12 Robofon
13 CESA 200
(001-014 Transmissions)
(001-014 Transmissions,
000=disabled)
(001-014 Transmissions,
000=disabled)
(000-255 seconds)
(001-255 minutes)
No. of checks req'd (003-
255)
(001-255 days/minutes)
(000-255 days)
(000-255 days/hours)
(000-255 minutes)
[380] – First Communicator Option Codes
Opt
Default
Description
1
I__I
ON
Communications Enabled
OFF
Communications Disabled
2
I__I
ON
Restorals on Bell Time-out
OFF
Restorals Follow Zones
3
I__I
ON
Pulse Dialing
OFF
DTMF Dialing
5
I__I
ON
3rd Telephone Number Enabled
OFF
3rd Telephone Number Disabled
8
I__I
ON
Delinquency Follows Zone Activity (Hours)
OFF
Delinquency Follows Arming (Days)
[381] – Second Communicator Option Codes
The 3rd toggle option in this section is used to enable/disable auto-
matic SIA reporting. The 5th toggle option is used to enable/disable
automatic Contact ID reporting. Configure the options as required and
press [#] to exit.
NOTE:If the automatic SIA or automatic Contact ID reporting formats
are not used, reporting codes must be programmed. To program
reporting codes refer to the PowerSeries PC1616/1832/1864 Refer-
ence Manual which can be downloaded from the DSC web site at
www.dsc.com
Opt
Default
Description
3
I__I
ON
SIA Sends Programmed Reporting Codes
OFF
SIA Sends Automatic Reporting Codes
5
I__I
ON
Contact ID Uses Programmed Reporting
Codes
OFF
Contact ID Uses Automatic Reporting Codes
[382] – Third Communicator Option Codes
The 4th toggle option in this section is used to enable/disable Call
Waiting Cancel. Configure the options as required and press [#] to exit.
NOTE:A Call Waiting Cancel on a Non Call Waiting line will prevent
successful connection to the central station.
Opt
Default
Description
4
I__I
ON
Call Waiting Cancel Enabled
OFF
Call Waiting Cancel Disabled
5
I__I
ON
T-Link Interface Enabled
OFF
T-Link Interface Disabled
[701] – First International Options Codes
Option 7 in this section Selects Battery Charge Options.
Select ON for 7 Ahr and 14 Ahr batteries (700 mA charge rate)
Select OFF for Standard 4 Ahr batteries (400 mA charge rate)
Opt
Default
Description
7
I__I
ON
High Current Battery Charge (700mA)
OFF
Standard Battery Charge Rate (400mA)