DSC PowerSeries PC1832 Installation Manual - Page 9
Browse online or download pdf Installation Manual for Security System DSC PowerSeries PC1832. DSC PowerSeries PC1832 13 pages. System
enhancement
module
Also for DSC PowerSeries PC1832: Installation Manual (17 pages), Installation Manual (20 pages), Manual (18 pages)
SIA False Alarm Reduction Installations: Quick Reference
SIA Feature Programming Section
Exit Time - [005], 3rd entry
Progress Annunciation/ Disable - for Silent
Exit -
[014], Option 6 ON
Exit Time Restart -
[018], Option 7 ON
Auto Stay Arm on Unvacated Premises -
[001]-[004] Zone type 05, 06
Exit Time and Progress
Annunciation/Disable or Remote Arming -
[005] and [014] bit 6
Entry Delay(s) - [005], 1st and 2nd entry
Abort Window for Non-Fire zones - [101]-
[164] bit 7 ON
Abort Window - for Non-Fire zones - [377],
4th entry
Abort Annunciation - [382], Option 3 ON
Cancel Annunciation - [328], 8th entry
Duress Feature - [ ][5] Master Code - [99]
Option 2 ON
Cross Zoning - [018]
Option 6 ON
[101]-[164] bit 9 OFF
Cross Zone Timer - [176]
Swinger Shutdown for Alarms
[377] 1st entry
Swinger Shutdown Disable -
[101] - [164] bit 6 ON
Fire Alarm Verification - Zone Type [29]
Call Waiting Cancel Dial String - [304],
[382], Opt. 4 OFF
System Test: [ ][6] Master Code, Option 4
Installer Walk Test Mode: [901]
Alarm Communications During Walk Test
[382] Opt. 2
Walk Test End and Begin Reporting Codes
st
nd
[348], 1
and 2
Entries
PowerSeries PC1616/PC1832/PC1864 Installation Guide
Comments
Access to Entry and Exit delays for each partition and Bell Time Out for the
system
Enables audible exit beeps from the keypad for the duration of exit delay
Enables the exit delay restart feature
Function Key: Stay Arming. All Stay/Away type zones (05, 06) will be
automatically bypassed
System Times and Audible Exit beeps can be disabled when using the Key fob to
away arm the system
Access to Entry and Exit delays for each partition and Bell Time Out for the
system. NOTE: Combined Entry delay and Communications Delay (Abort
Window) shall not exceed 60s
Access to zone attributes, i.e, swinger shutdown, transmission delay and cross
zone. Individual zones attribute bit 7 (Transmission delay) is by default ON
Access to the programmable delay before communicating alarms. NOTE:
Combined Entry delay and Communications Delay (Abort Window) shall not
exceed 60s
Enables the "Communication Cancelled" message display on all keypads
Access to the reporting code for Alarm Cancelled
Do not derive code from an existing Master/User code (e.g., Master code is 1234,
the duress code should not be 1233 or 1235)
This option enables Cross Zoning for entire system. Individual zones can be
enabled for Cross zoning via Zone attribute bit 9 in sections [101] - [164]
Access to the programmable Cross Zone timer
Access to the swinger shutdown limit for zone alarms
Access to zone attributes, i.e., swinger shutdown, transmission delay and cross
zone. Individual zones attribute bit 6 (Swinger shutdown enabled) is by default
ON
Auto Verified Fire, use only with 4 wire type detectors that can be reset by the
panel 4-wire smoke detector powered from AUX + and PGM1 - PGM4 (type 03,
Sensor reset)
Access to the dialing sequence used to disable call waiting
The system activates all keypad sounders, bells or sirens for 2 seconds and all
keypad lights turn on.
Refer to the User Manual (part no. 29008261)
This mode is used to test each zone on the system for proper functionality
Enables Communication of zone alarms while installer Walk Test is active
Access to the reporting codes for Walk Test Begin and Walk Test End
Testing
- 9 -
Range/Default
Requirement
For Full or auto arming:
Required
Range: 45-255 seconds
(programmable)
Default: 60 sec.
Individual keypads may be
Allowed
disabled
Default: All Enabled
Default: Enabled
Required
If no exit after full arm
Required
Default: Enabled
Default: Enabled
Allowed
Range: 30 sec. to 4 min.
Required
Default: 30 sec.
(programmable)
May be disabled by zone or
Required
zone type
Default: Enabled
Range: 15 - 45 sec.
Required
Default: 30 sec.
(programmable)
Annunciate that no alarm was
Required
transmitted
Default: Enabled
Annunciate that a Cancel was
Required
transmitted
Default: Enabled
No 1+/- derivative of another
Allowed
user code. No duplicates with
other user codes
Default: disabled
Programming required
Required
Default: Disabled
May program
Allowed
Range: 001-255 sec.
Default: 60 secs
For all non-fire zones shut
Required
down at 1 or 2 trips
(programmable)
Default: 1 Trip
For non-police response zones
Allowed
Default: Enabled
70 seconds reset and
Required
confirmation time
Default: disabled
Dependant on user phone line
Required
Default: disabled