DSC PowerSeries PK5501 Instruction Manual - Page 10
Browse online or download pdf Instruction Manual for Security System DSC PowerSeries PK5501. DSC PowerSeries PK5501 20 pages. Power pk55xx/rfk55xx-433 series
Also for DSC PowerSeries PK5501: Installation Instructions Manual (9 pages)
Trouble Conditions
When a trouble condition is detected, the Trouble ( ) or System indicator will turn on, and the key-
pad will beep every 10 seconds. Press the
trouble condition. The Trouble ( ) or System indicator will flash. The corresponding trouble will be
represented by numbers 1-8.
Trouble
LED/
DIGIT
Condition
1
Service Required
(Press [1] for
more informa-
tion)
2
Loss of AC Power
3
Telephone Line
Fault
4
Failure to Com-
municate
5
Sensor (or Zone)
Fault
6
Sensor (or Zone)
Tamper
7
Sensor (or Zone)
Low Battery
8
Loss of Time &
Date
Alarm Memory
When an alarm occurs, the Memory or System indicator (and Fire indicator, if applicable) will turn on.
To view which sensor(s) generated the alarm, press
responding sensor number will flash (i.e. sensor 3).
For the PK5500/RFK5500 keypad use the
Press
to exit. To clear the memory, arm and disarm the system.
If an alarm sounded while armed, the keypad will automatically go to alarm memory when you dis-
arm the system. In this instance, you should approach with caution, as the intruder may still be within
the building/premises.
Door Chime (Entry/Exit Beeps)
To turn the door chime function on or off, press and hold the Chime key (
press
.
Comments
(1) Low Battery (2) Bell Circuit (3) System Trouble (4)
System Tamper (5) Module Supervision (6) RF Jam
Detected (7) PC5204 Low Battery (8) PC5204 AC Fail-
ure
If the building and/or neighbourhood has lost electri-
cal power, the system will continue to operate on
battery for several hours.
The system has detected that the telephone line is
disconnected.
The system attempted to communicate with the
monitoring station, but failed. This may be due to
Trouble 3.
The system is experiencing difficulties with one or
more sensors on the system. Press 6 to display the
zone.
The system has detected a tamper condition with one
or more sensors on the system.
If the system has been equipped with wireless sen-
sors, one or more has reported a low battery condi-
tion.
If complete power was lost (AC and Battery), the time
and date will need to be re-programmed.
key to silence the beeps. Press
. The Memory or System indicator and cor-
scroll keys to view the sensors in alarm memory.
8
to view the
Action
Call for service
Call for service
Call for service
Call for service
Call for service
Call for service
Call for service
Re-program
Time & Date
(page 6)
) for 2 seconds or