FoxESS R Series Quick Installation Manual
Browse online or download pdf Quick Installation Manual for Inverter FoxESS R Series. FoxESS R Series 2 pages.
Quick Installation Guide
1.Packaging List
A
B
C
G
H
F
K
L
M
P
Object
Quantity
Description
Object
Quantity
A
1
Inverter
I
B
1
Left Hanging Plate
J
C
1
Right Hanging Plate
K
Hanging Plate
D
1
L
Connection Bar
E
4
Screw-in Type Handle
M
F
4
M10*45 Bolt Assembly
N
G
4
M10 Hexagon Nut
O
H
2
M6*50 Bolt Assembly
P
2.Inverter Installation
Please make sure the inverter will be installed with a proper
distance as shown below.
Position
≥200
Left
≥600
Right
≥600
Top
≥1000
Bottom
≥450
Front
R Series Inverter
Step 1: Hanging Plate Assembly
Install the Inverter on a bracket or wall by means of the
hanging plate. The hanging plate assembly diagram and the
size of the assembled hanging plate are shown as below:
D
E
I
J
Quick
Installa�on
Guide
N
O
Description
M4*10 Screw
4
DC Connector
Step 2: Bracket-mounted Installation or Wall-mounted Installation
36
(Positive*18, Negative*18)
DC Pin Plug
Mode 1: Bracket-mounted Installation
36
(Positive*18, Negative*18)
1. Place the assembled hanging plate on a PV bracket, adjust
1
Communication Connector
the angle with a level, mark drilling positions, and drill holes
2
Ground Terminal
with an electric drill (with a φ12 drill bit).
5mm Internal
1
Hexagon Wrench
1
Quick Installation Guide
1
WIFI/4G/USB(Optional)
2. Fix the hanging plate with bolts.
Min Size
600 mm
A
600 mm
200 mm
450 mm
A: 4 PCS of M10*45 hexagon bolts
1000 mm
B: 4 PCS of hexagon nuts
1
4 PCS of M4*10 screws
Hanging Plate Assembly Diagram
898
850
802
4-
12
φ
48
50
The Size of Hanging Plate
B
Mode 2: Wall-mounted Installation
1.Place the assembled hanging plate at the installation site, adjust
the angle with a level, and mark drilling positions.
2.Drill holes with a hammer drill (with a φ12 drill bit), clear
holes, insert 4 PCS of expansion bolts (by client, M10*95 is
recommended) into holes, and fix them with a rubber hammer.
3.Fix the hanging plate with expansion bolts.
B
A
A: 4 PCS of M10 hexagon nuts
(M10)
C: Wall
Step 3: Inverter Installation
1.Lift the inverter from the package box with 4 PCS of screw-in
type handles.
2
C
B: 4 PCS of expansion bolts
Screw-in type handle
3