2.Function explanation
2-1
Input voltage
・ Input voltage range is single phase alternating
current. 85~264Vac(47~63Hz).
・ We recommend that you do not use this power
supply unit outside of it's normal intended use in
order to avoid any damage or malfunctions.
2-2
Output voltage setting
・ You can adjust +Vout by using Output Voltage
Adjustment Potentiometer that is next to the
connector (CN501).
・ You can increase output voltage by turning clockwise.
If you need decrease, you can turn it the other way.
・ Please use it within the following range when you
adjust the output voltage.
・Within +/- 10% lated output voltage.
・Do not use maximum output power.
・ Do not exceed rated output current.
2-3
Inrush Current
・ The inrush current limiting circuit is built-in
・ The inrush current limiting circuit is built-in.
・ The inrush current limiting circuit might released it
when the input re-turning on time is short, because
SCR is used for the inrush current limiting. So turn it
on again enough after time.
・ The first inrush current and the second inrush
current flow because it adopts SCR method for the
inrush current limiting circuit.
2-4
Over-current Protection(OCP)
・ The over-current protection works and the output is
intercepted when becoming 110% or more of the
output current ratings.
・ Remove the factor of the overload, and turn on the
input again after a few minutes of cutting when
resetting it.
・ Please avoid operation in the over-current state
for 10 seconds or more.
It will cause damage or isolation failure.
2-5
Over-Voltage Protection(OVP)
・ It is detected when the output voltage rises by some
causes, and the output is intercepted at once.
・ When it works once, the over-voltage protection
continues the output interception while the input is
supplied.
・ Turn it on again after a few minutes after intercepting
the input when resetting it.
・ Note that the output voltage might be abnormal when
you turn it on again. (In this case, the over voltage
protection works again. )
2-6
Remote On/Off circuit
・ The remote control function is built-in.
・ You can control the output in On/Off by applying
the voltage.
・ You can control it by applying the external voltage
to the RC Connector, which is secondary circuit of
power supply. It can't be used in primary side circuit.
Connector(CN501)
1kΩ
⑦ +R
⑧ -R
Power Supply
Voltage level -Pin #7 & #8.
SW OFF
Less than 0.8V, or Open
SW ON
4.5V~12.5V
Please connect external resistor R when using
6.5V or more in an impressed voltage.
External Voltage level:E
External Voltage level:E
4.5~12.5VDC
12.5V~24.5VDC
E-(1.1+1000×0.005)
R Ω =
2-7
Remote Sensing
・ The remote sensing function is built-in.
・ Line drop between the top (the load device side)
and power supply terminal of the sensing line use it
by 0.3V or less. Please note that power supply
terminal voltage does not become out of a rating
range.
・ The sensing wire is done in the twist. And it uses it
along the load wire.
Power Supply
Load wire
Switch
1
(SW501)
0
Connector
③ -S
(CN501)
① +S
・ Please confirm that the switch is "0", in the case
that it does not use remote sensing.
When the factory is shipped, the switch is "0", and
the power supply can be used as it is when the
remote sensing is not used.
SW
ON
R
E
OFF
Output
ON
OFF
External Resistor:R
External Resistor:R
No Required
* Refer to the following
0.005
Load