ENGLISH
Read the Operating Instructions carefully before use.
Save these instructions for future reference.
IMPORTANT:
Disconnect the power supply before electrical installation.
The power cord must be waterproof and VDE marked, and of the H05RN-F 3 x 1.0 mm² type. A
damaged power cord must be replaced by an authorised service centre, or qualified person, to
ensure safe use.
The product must be connected to a protective earth.
Do not use the product if the glass cover is cracked. Replace the glass cover immediately. Only
use original spare parts.
The product is intended for permanent installation.
The bulb cannot be replaced. If the bulb stops working, the entire fitting must be replaced.
Operating temperature: -10 to 50℃.
ELECTRICAL SAFETY
New installations and extensions to existing systems should always be carried out by an authorised
electrician. If you have the necessary experience and knowledge, you may replace switches and power
points, fit plugs, extension cords and light sockets. If not, you should contact an electrician. Incorrect
installation can result in electric shock or fire.
Rated voltage
Rated output
Protection rating
Luminous flux
Max. installation height
Dimensions
Weight
1.
Undo the bracket.
ENGLISH

SAFETY INSTRUCTIONS

TECHNICAL DATA

INSTALLATION

2.
8
230 V ~ 50 Hz
50 W
IP65
3500 lm
3 m
320 x 100 x 390 mm
4.4 kg
Fit the bracket to the supporting surface and
pull the power cord through the hole in the
middle.