S
1.1 Features
The PC5108L serves three purposes:
• To expand the PC5015 v2.2 alarm control panel's zone capability
by adding eight fully programmable zone inputs
• To act as an interface between the DLM-4L v1.0L Video
Transmission module and the PC5015 v2.2 alarm control panel
• To function as a video switcher
1.2 Specifications
• Current rating: 60mA
• Eight fully programmable zones
• Maximum of eight video cameras
• VAUX+ rating: 12 VDC, fused @ 250mA
1.3 Additional Equipment
• Control panel compatibility: PC5015 v2.2
• Downlook module compatibility: DLM-4L v1.0L
• Keypad compatibility (for Active Camera Monitor Selection
function key): LCD5500Z v2.X and PC55XX v2.X
• Downloading software: DLS-1 v6.5
• Local downloading: PC-Link
• Compatible cabinets:
PC4002C – space for PC5108L plus two other modules of same
dimension