DF-C 63XXX & 61XXX Series User's Manual
Version 28.04.2019
3.3 Power ON
Set the „ON / OFF" switch to the ON position to turn on the device. The device is equipped with a soft-start delay which
slowly charges the capacities in the power supply to limit the high inrush currents. After about 10 seconds, the power
supply will switch into stand-by mode.
3.3.1 Stand-By Mode
The output is switched off in stand-by mode and the device is ready to set the desired output values. The displays
show a voltage of 0V and a current of 0A, which corresponds to the actual values at the output.
Press the SET button once to enter the setup menu.
Press the SET button once
- FREQUENCY display flashes -> Frequency setting
Press the SET button 2x
- VOLTAGE display flashes -> Voltage setting
Press the SET button 3x
- VOLTAGE display flashes -> FLOAT + percentage setting (default 10%)
Press the SET button 4x
- VOLTAGE display flashes -> FLOAT- percentage setting (default -10%)
Press the SET button 5x
- CURRENT display flashes -> Setting of Over Current Protection value
(In the range 0 - max. output current of the power supply / max. 0 - 50A)
Press the SET button 6x
- Save settings, back to stand-by mode
3.3.3 Setup Menu (CV Version) DF-C61XXX
Press the SET button once to enter the setup menu.
Press the SET button once
- FREQUENCY display flashes -> Frequency setting
Press the SET button 2x
- VOLTAGE display flashes -> Voltage setting
Press the SET button 3 x
- CURRENT display flashes -> setting of the Over Current Protection value
(In the range 0 - max. output current d of the power supply / max. 0 - 50A)
Press the SET button 4x
- Save settings, back to stand-by mode
3.3.4 Setting the output values for constant current sources of the DF-C series (CC version)
Constant current sources of the DF-C series which work in CC mode have no setup menu and a simplified Control
panel. If you are in stand-by mode (output OFF), values can be entered directly using the arrow keys, saving is not
necessary.
3.3.5 Voltage Range Setting (LV / FS)
Press the LV / FS key to switch between the voltage ranges, the currently set voltage range is displayed on the
frequency display for 3 seconds with L for LV and F for FS. Normally the range is LV for 0 - 150V and FS for 0 - 300V,
this may differ for custom-made devices.