3onedata IES2100SL-16T-2LV Quick Installation Manual - Page 3
Browse online or download pdf Quick Installation Manual for Switch 3onedata IES2100SL-16T-2LV. 3onedata IES2100SL-16T-2LV 3 pages. Unmanaged industrial ethernet switch
DIP Switch Definition
Operation
Storm
Set the switch to ON to enable
2
Suppression
storm suppression function
Set the DIP switch to ON, Port
1 is uplink port, Port 2-5 are the
3
VLAN
downlink ports, and the
downlink ports are isolated
from each other.
Flow
Set the switch to ON to enable
4
Control
flow control function
Model II
DIP
Definition
Operation
Switch
Set the switch to ON to enable port
loop detection function. When the
Loop
loop is detected, the communication
1
Detection
of one port will be blocked to avoid
the storm, and the indicator of the
loop port will flash to warn.
Storm
Set the switch to ON to enable storm
2
Suppression
suppression function
Set the DIP switch to ON, Port 1 is
uplink port, Port 2-8 are the downlink
3
VLAN
ports, and the downlink ports are
isolated from each other.
Flow
Set the switch to ON to enable flow
4
Control
control function
Model III
DIP
Definition
Operation
Switch
Set the switch to ON to enable flow
1
Flow control
control function
Storm
Set the switch to ON to enable storm
2
Suppression
suppression function
3-4
NC
Reserved
Notice:
The functions corresponding to the 4 DIP switches
cannot be used at the same time. You can select one of
them to set the function.
【Checking LED Indicator】
Provide LED indicators to monitor its operating status, which
has simplified the overall troubleshooting process. The
function of each LED is described in the table below:
LED
Indicate
Description
ON
Power supply is running normally
P1-P2
Power supply is disconnected or
OFF
running abnormally
The device is powering on or the
ON
device is abnormal.
RUN
Blinking
The device is running normally
The device is powered off or the
OFF
device is abnormal.
Ethernet port has established a valid
ON
network connection
Ethernet port
network status
Note:
1-5/8/16
Blinking
If loop detection is enabled and the port
is looped, the loop port indicator would
flash at a frequency of 1Hz for warning.
Ethernet port has not established a
OFF
valid network connection.
【Specification】
Panel
100M copper port
10/100Base-T(X) self-adaptive
RJ45, full/half duplex mode
self-adaption,
autotunning
Indicator
Power
indicator, interface indicator
Switch Property
Model I
MAC address table: 2K
Backplane bandwidth: 1G
Model II
Model III
Power Supply
Input power supply
Access terminal block
Power Consumption
Model I
Model II
Model III
Working Environment
Working temperature
is in an active
Storage temperature
Working humidity
Protection grade
MDI/MDI-X
indicator,
running
MAC address table: 2K
Backplane bandwidth: 1.6G
MAC address table: 8K
Backplane bandwidth: 3.2G
12/24/48 VDC(9~60VDC), dual
power
supply
redundancy,
support anti-reverse connection
4-pin 5.08mm pitch terminal
blocks
No-load: 0.2W@12VDC
Full-load: 0.8W@12VDC
No-load: 0.4W@12VDC
Full-load: 3.0W@12VDC
No-load: 0.7W@48VDC
Full-load: 2.9W@48VDC
-40~75℃
-40~85℃
5%~95% (no condensation)
IP40 (metal shell)