Boundary Devices Nitrogen8M User Manual - Page 8
Browse online or download pdf User Manual for IP Access Controllers Boundary Devices Nitrogen8M. Boundary Devices Nitrogen8M 15 pages. Nitrogen access control
Nitrogen Access Control User Manual
2.NITROGEN WIRING
2.1 WIRING DIAGRAMS
2.1.1 DOORLOCK/TURNSTILE CABLE
PIN #
DESCRIPTION
Green LED Control - Open-Collector Transistor output with 600mA limit used primarily to control LEDs.
1
Default software programmed to be connected to Green LED
+12V - In non-POE models, this needs to be wired to a +12V/3A DC power supply. In POE models, this
2
is a +12V 600mA max output that can be used to power LEDs or a door strike
Red LED Control - Open-Collector Transistor output with 600mA limit used primarily to control LEDs.
3
Default software programmed to be connected to Red LED
+12V - Internally same as Pin 2. In non-POE models, one of the RED wires (pin 2 or 4) should be
4
connected to +12V/3A DC input and the other RED wire can be used to power the LEDs or a door strike
5
Feedback Input 1 - Diode-protected input used primarily to receive feedback from a switch
6
GND - Negative Supply
7
Feedback Input 2 - Diode-protected input used primarily to receive feedback from a switch
8
Dry Contact - Max Load Current 0.6A
9
Dry Contact - Max Load Current 0.6A
GND – Negative Supply
10
R E V I S I O N
| 1 . 5 A
|
www.boundaydevices.com
P A G E
| 5