3onedata IES6210 Series Quick Installation Manual - Page 3

Browse online or download pdf Quick Installation Manual for Switch 3onedata IES6210 Series. 3onedata IES6210 Series 4 pages. Managed industrial ethernet switch

3onedata IES6210 Series Quick Installation Manual
Power input voltage of model VI model VIIand model X:
48VDC, power input voltage of model I and model III: 48VDC
(12~48VDC).
AC power supply 220VAC
This series of model II and model IV
support AC single power supply and
provide 6 pins 5.08mm pitch input
terminal blocks, including 4 pins power supply terminal blocks
on the left side.
Power input voltage: 220VAC (85~264VAC).
【Relay Connection】
The device provides 6-pin 5.08mm pitch
input terminal blocks , including 2-pin
relay terminal blocks on the right side.
Relay terminals are a pair of normally
open contacts in device alarm relay.
They are open circuit in normal non alarm state, closed when
any alarm information occurs. Such as: it' s closed when power
off, and send out alarm. The switch supports 1 channel relay
alarm information output, support DC power alarm information
or network abnormal alarm output, it can be connected to
alerting lamp, alarm buzzer, or other switching value collecting
devices for timely warning operating staffs when alarm
information occurs.
【DIP Switch Settings】
Provide 4 pins DIP switch for function settings,
where "ON" is enable valid terminal. Please
power off and power on after changing the status
of DIP switch. DIP switch definition as follows:
DIP
Definition
Operation
Set the DIP switch to ON, power
Restore
on the device again, it will
1
factory
restore to factory settings, then
defaults
turn off the DIP switch.
2
Reserved
-
Set the DIP switch to ON, the
3
Upgrade
program of this device can be
DIP
Definition
Operation
upgraded, then turn off the DIP
switch
completes.
4
Reserved
-
【Console Port Connection】
The device provides 1 channel procedure debugging port
based on serial port, and can conduct device CLI command
line management after connected to PC. The interface adopts
RJ45 port, the RJ45 pin definition is as follows:
Pin No.
2
3
Definition
TXD
RXD
【Checking LED Indicator】
The function of each LED is described in the table as below:
LED
Status
Description
Power supply is connected
ON
and running normally
P1/P2/PWR
Power supply is
OFF
disconnected and running
abnormally.
Power supply, port link
ON
alarm
ALM
Power supply, port link
OFF
without alarm
The device is powered on or
ON
the device is abnormal.
RUN
The device is powered off or
OFF
the device is abnormal.
Blinking
System is running well.
Ethernet port connection is
ON
active.
Link/ACT
Blinking
Data transmitted
(1-4/8, G1-G2)
Ethernet port connection is
OFF
inactive.
POE port supply electricity
ON
for other devices normally
POE (1-4/8)
OFF
POE is disabled or
【Logging in to WEB Interface】
when
this
upgrade
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
way of logging in to device's configuration interface via IE
browser is shown as below:
Step 1
Step 2
5
GND
Step 3
Step 4
Note:
disconnected
Configure the IP addresses of computer and the
device to the same network segment, and the
network between them can be mutually accessed.
Enter device's IP address in the address bar of the
computer browser.
Enter device's username and password in the login
window as shown below.
Click "OK" button to login to the WEB interface of
the device.
The default IP address of the device is "192.168.1.254".
The default username and password of the device is
"admin".
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared