ATX SignalOn Series Installation & Operation Manual - Page 11

Browse online or download pdf Installation & Operation Manual for Switch ATX SignalOn Series. ATX SignalOn Series 16 pages. L-band splitter module
Also for ATX SignalOn Series: Installation & Operation Manual (16 pages)

OPERATING INSTRUCTIONS

3.
Operating Instructions
There are no specific operating instructions for the SignalOn Return Path Amplifier. Once the amplifier is installed, it will
perform its designated RF signal management function without further attention. As detailed below, the amplifier includes
convenient Monitor (MON) ports where test equipment can be connected to the system as necessary.
3.1.

Monitor Test Ports

Two 20 dB monitor test ports are standard on the Return Path Amplifier, one before RF amplification and one after.
3.2.

Reverse Path

SignalOn modules can balance the reverse path combined signals and provide the balanced power from the reverse path
receivers to signal processing equipment (e.g., cable data modems, HDTs, etc.). (See example in Figure 3.)
FROM
NODE 1
FROM
NODE 1
SignalOn
Series – Return Path Amplifier – Installation & Operation Manual
®
4 x 1
RETURN PATH
RECEIVER
SPLITTER
4 x 1 WITH PLUG-IN
ATTENUATION PADS
AND MONITOR PORT
4 x 1
RETURN PATH
SPLITTER
RECEIVER
4 x 1 WITH PLUG-IN
ATTENUATION PADS
AND MONITOR PORT
Figure #3: Reverse Path Example
CHAPTER 3: OPERATING INSTRUCTIONS
2 x 1
COMBINER
RETURN
PATH
AMPLIFIERS
2 x 1
COMBINER
CABLE
DATA
MODEM
HOST
DIGITAL
TERMINAL
(HDT)
3-1