Comtrol RocketPort 485 Hardware Installation - Page 6
Browse online or download pdf Hardware Installation for PCI Card Comtrol RocketPort 485. Comtrol RocketPort 485 8 pages.
Setting the DIP Switches
The RocketPort ISA card uses a DIP switch to set the base
I/O address range. The default value is 180 (hex). If you
are installing more than one RocketPort card, or if you
experience an I/O address conflict with another device, use
the DIP switches to change the I/O address.
For example, if you install two RocketPort cards and are
using the default address range:
Sample DIP Switch Settings
1st RocketPort
180 (hex)
2nd RocketPort
(Software address can be
any unused I/O address)
The following table lists possible DIP switch settings. We
recommend starting with the default settings and making
changes only if the default values produce conflicts.
First ISA Card DIP Switch Settings (see Notes)
100 - 143 hex
140 - 183 hex
ON
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
240 - 283 hex
200 - 243 hex
ON
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
300 - 343 hex
340 - 383 hex
ON
ON
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Notes:
1. If installing a single RocketPort ISA card, set the DIP
switches as shown in the table.
2. If installing two ISA cards, set the DIP switches on the
second card the same as the switches on the first card,
EXCEPT SWITCH 5 OFF.
3. If installing three ISA cards, follow Note 2 for the second
card, then set the DIP switches on the third card the
same as the switches on the first card, EXCEPT
SWITCH 6 OFF.
4. If installing four ISA cards, follow Notes 2 and 3 for the
second and third cards, then set the DIP switches on the
fourth card the same as on the first card, EXCEPT
SWITCHES 5 AND 6 OFF.
RocketPort® 485 Hardware Installation
ON
1st Card
1
2
3
4
5
6
7
8
ON
2nd Card
1
2
3
4
5
6
7
8
180 - 1C3 hex
ON
1 2 3 4 5 6 7 8
280 - 2C3 hex
ON
1 2 3 4 5 6 7 8
380 - 3C3 hex
ON
1 2 3 4 5 6 7 8
Specifications
The following tables illustrate RocketPort conditions and
specifications.
Environmental Condition
Air temperature:
System on
System off
Humidity (non-condensing):
System on
System off
Altitude
Electromagnetic Compliance
Emission:
Canadian EMC requirements
CISPR-22/EN55022 Class A
FCC PART 15: Class A
Immunity:
EN50082: 801-2 ESD, 801-3 RF,
801-4 FT
UL Recognized
RocketPort 485 Card
Baud Rate:
Note: Baud rate is dependent upon hardware and
operating system configuration.
Bus interface
Note: EISA files are on the Diagnostics diskette.
Control by device driver:
Data bits
Parity
Stop bits
Current Consumption
(Values do not include
the power supplied to
external devices on
Ports 3 through 8.)
Dimensions
Heat output
Interfaces:
All models
With optional RS-485
feature enabled on
Ports 1 and 2
Interrupt (software
selectable)
Mean time between
failures (MTBF)
Power consumption
Value
o
0 to 40
C
-20 to 85
o
C
8% to 80%
20% to 80%
0 to 10,000 feet
Status
Yes
Yes
Yes
Specification
50 to 460.8K bps
ISA
7 or 8
Odd, Even, None
1 or 2
+5V
+12V
-12V
350 mA 110 mA 160 mA
6.25" by 4.2"
16.6 BTU/Hr
RS-232
RS-485
None, 3, 4, 5, 9, 10, 11, 12, 15
20.5 Years
4.87 W
6 of 8