NOTE:
The CT240 will automatically hang up if no key is pressed
during the 30 seconds following the CT240 answering a call.
Default values:
• Access code = 1234
• Number of rings = 4
Dial your phone number
Wait for the number of rings...
CT240 answers
Dial your phone number
Let it ring once and hang up
Wait 10 seconds...
Dial your phone number again within the next 30 seconds
CT240 answers (1st ring)
Enter your 4-digit access code
(default: 1234)
Press
for output status
Press
to change status
Press
Enter your new 4-digit access code
Enter the access code again
Press
Enter the number of rings after
which the CT240 will answer
(between 1 and 9)
Press
to end the session
The button, located on the upper-left corner of the CT240, can be
used to manually switch the relay status. This option is not available
while the CT240 is answering a telephone call.
The light is ON when the auxiliary output is in Vacation mode (termi-
nals 1 and 2 closed)
Insert a pointed object (e.g. paper clip) in the hole located under the
Reset light. The light will flash 3 times to indicate that the CT240 has
been reset:
• number of rings: 4
• access code: 1234
• Output status:
Power
Output
Maximum load for parallel connection of Aube thermostats: 50 mA
Auxiliary output
• 5 A / 30 VAC inductive / Power Factor: 0.4
• 10 A / 30 VAC resistive (if installed in a certified electrical box)
• 10 A / 240 VAC resistive (if installed in a certified electrical box)
• 1/2 HP / 120 VAC motor (if installed in a certified electrical box)
• 1 HP / 240 VAC motor (if installed in a certified electrical box)
Protection: Class II
Access code
Number of rings
Memory
put status are protected.
Phone certification
• FDTBR21: European telephone network
Accepted
• FCC68: North American telephone network
Error
Approvals:
• c UL us (North America)
• CE (Europe)
Dimensions (H W
Comfort
Vacation
AUBE TECHNOLOGIES INC. THREE (3) YEAR LIMITED WARRANTY
This product is guaranteed against workmanship defects for a three-
year period following the initial date of purchase. During this period,
AUBE Technologies Inc. will repair or replace, at our option and with-
out charge, any defective product which has been used under normal
conditions. The warranty does not cover delivery costs and does not
apply to products poorly installed or randomly damaged following
installation. This warranty cancels and replaces any other manufac-
turer's express or implied warranty as well as any other company
Accepted
commitment. AUBE Technologies Inc. cannot be held liable for
Error
related or random damages following the installation of this product.
The defective product as well as the purchase invoice must be
returned to the place of purchase or mailed, prepaid and insured, to
the nearest shipping address.
x the number of
selected rings
ABC: Terminals A and C: Comfort
123: Terminals 1 and 2: opened, Terminals 2 and 3: closed
supply: 9 VAC / 60 Hz (50 Hz Europe)
(ABC): 0 VDC = Comfort mode / 12 VDC = Vacation mode
(123): SPDT with following capacity:
(default): 1234
(default): 4 rings
protection: In case of power failure, access code and out-
standard:
D): 2.7 x 5.4 x 1.2 in. (69 x 137 x 31 mm)
705 Montrichard
Saint-Jean-sur-Richelieu
Quebec, Canada J2X 5K8
Tel.: (450) 358-4600
Toll
Free: 1-800-831-AUBE
Fax: (450) 358-4650
For more information on our products,
visit us at
www.aubetech.com
10 Ampère Street
95500 Gonesse
France
33 (0) 1 34 07 99 00
33 (0) 1 34 07 99 19
29/10/2003