Auber Instruments WSD-1500GPH Quick Manual - Page 14

Browse online or download pdf Quick Manual for Temperature Controller Auber Instruments WSD-1500GPH. Auber Instruments WSD-1500GPH 14 pages. Programmable pid temperature controller with dual probe

Auber Instruments WSD-1500GPH Quick Manual
Before you input your program, check the PrG = on (accessed by LCK code "3"). Long
press SET, set LCK=2, choose b1, press set to exit.
Then recipe b1 is recalled back as the current program. The controller is back to the
normal operating mode and will start run the current program.
c. Store your program as recipe (Single-step Mode)
Before you input your set temperature, check the PrG = off (accessed by LCK code "3").
Press SET key once, and then set C-1=150, press set again to confirm and exit. The
controller will go back to the normal operating mode and start running on this single-step
program.
To store current program back to recipe b2, long press SET, set LCK=2, choose b2,
press set to confirm and exit. Now your current program is stored as recipe b2.
d. Recall your recipe to current program (Single-step Mode)
Before you input your set temperature, check the PrG = off (accessed by LCK code "3").
Long press SET, set LCK=1, choose b2, press set to confirm and exit.
Now the C-1 from the recipe b2 is recalled back to your current program. The controller
will start run at this temperature setting.
e. Advanced example.
This example will show you how the PrG mode can affect the saved and current
recipe/program.
1) Set PrG = on, select "b1" recipe:
C-1=120, E-1=t, t-1=2.0;
C-2= 290, E-2= F, F-2=160;
C-3=130, E-3=t, F-3=30.0.
2) Change PrG = off, now the current single-step program is:
C-1: 120.
3) Set current C-1 to 200, then store current program back to recipe b1. Now the b1
recipe is:
C-1: 200.
4) Change PrG = on, current b1 recipe is:
C-1=200, E-1= t, F-1=2.0;
C-2=190, E-2=F, F-2=160;
C-3= 130, E-3=t, F-3=30.0.
14