AUBER INSTRUMENTS
10. Quick Operation Guide
If you see "Err" message in the display window, check the sensor and
sensor cable connection.
To run the program: if the controller is in Hold or Stop mode, press the
START key. The RUN indicator should be lit up.
To hold the program: when the program is running (RUN indicator on),
short press the PAUSE key to put the program on hold.
To stop the program: put the program to Hold mode, then long press the
STOP key for 4 seconds until you see "Stop" in the display window.
To set up program steps: press the SET key.
To set up system parameters: long press the SET key for 2 seconds.
To mute the alarm: press the MUTE key.
To check the current step number and the step running time: in the
Program Run Mode, press the STEP key once, the display will show "P-X",
where X is the current step number, then the display window will show the
elapsed time in the current step.
To check the total time since the controller is powered up: in the Program
Run Mode, press the STEP key twice. The display window will show "toL" and
will display the total time since controller is powered up.
To start from a specific step (or jump to a specific step): when the program
is on hold or stopped, press the STEP key once, and it will show "J-X"(where X
is the current step number). Use the UP or DOWN keys to change the step
number to the desired value, then press the START key to confirm. The display
will show JMP ("JUMP") for a second and then the controller will start
executing the specified program step.
11. Connect the Sensor to the Controller
The connector of sensor contains a slot for fitting pin connection. It also has a
spring lock to prevent disconnections from accidental pulling on the cable.
To install the sensor to the controller: 1) Identify the key on the male sensor
connector (Figure 5, a) and the notch on the female connector (Figure 5, b). 2)
Hold the tail of the female connector, align the notch and the key, and push the
female connector forward.
To remove the connector, hold the spring loaded collar on the female
connector and pull it back. Please see Figure 6.
2022.01
(a)
Copyright © 2022 Auber Instruments Inc. All rights reserved.
No part of this datasheet shall be copied, reproduced, or transmitted in any way without
the prior, written consent of Auber Instruments. Auber Instruments retains the exclusive
rights to all information included in this document.
WWW.AUBERINS.COM
Figure 5. Install the sensor.
Figure 6. Remove the sensor.
Auber Instruments
5755 North Point Parkway, Suite 99
Alpharetta, GA 30022, USA
www.auberins.com