8. FAQs
8.1 A probe shows "-H-" when it is plugged in.
The "-H-" is a probe input error message, which usually indicates that no
probe is connected or the probe is defective. Plug this probe to another
sensor port or plug a good probe to this port to see if the error code
follows the probe or stays with the sensor port.
8.2 A probe reading appears to be jumping round.
Please swap with another good probe to see if the issue moves with the
probe or stays with the probe socket. If the probe connector is loose, the
wires inside the probe is broken or about to break, the reading may jump
around.
8.3 How to clean the probes.
Do NOT wash the probe. Only wipe the probe's stainless-steel sheath
with damped paper towel or cloth. Please also keep water out of the
probe connector as well.
8.4 Can I leave the controller, the fan, and the probes on the
smoker after each cooking?
No, please do NOT leave them outside on the smoker. After each use,
keep them in a dry and cool environment.
8.5 What if I have one cooking step ends with food temperature
but I have no plugged in a food probe?
If a cooking step's ending criteria is food temperature, however, no food
probe is plugged in, the controller will still maintain the pit temperature
but this step will never end.
2024.01
controller.

9. Additional Reading

9.1 Open-Lid Detection
When the lid of a smoker is opened during cooking, the pit temperature will
drop significantly and quickly. The derivative part of the PID algorithm (D)
reacts to this substantial temperature change, increasing the output and
causing the blower to run, potentially at maximum speed, to counteract the
temperature drop. This action may result in blowing up ashes, intensifying the
flame, and causing a significant temperature overshoot after the lid is closed.
The Open-Lid Detection function is specifically designed to prevent these
issues. When the smoker's lid or dome is opened, this function detects the
sudden temperature drop and halts the blower. After the lid is closed, and the
pit temperature is restored through the residual heat in the smoker, the blower
resumes operation. However, if after 7 minutes the temperature hasn't fully
recovered, the controller resumes sending output to the blower.
This Open-Lid Detection function is inactive when initially starting the fire. It
becomes operational once the pit temperature is less than 5 degrees lower
than the set temperature. While the open-lid detection might be triggered
accidentally by a temperature drop unrelated to lid-opening during smoking,
you can cancel this activation by pressing the TIME/BACK key on the
controller or tapping the 'X' (Cancel) symbol near 'Open-Lid Detection' on the
SYL-3615 device info page in the AuberWiFi app.
In situations where the Open-Lid Detection is activated by an actual lid-
opening action, it is recommended not to cancel this function to avoid
experiencing a pit temperature overshot. The controller can manage this issue
and minimize disturbance. However, if you are cooking at a higher
temperature range (> 300°F), and the pit temperature may not recover by
itself, it's advisable to cancel the activation in such cases.
If you want to manually pause the fan output temporarily, you can unplug the
fan connector from the controller. To resume the fan output, plug the fan's
connector back into the controller.
(End)
Auber Instruments Inc.
5755 North Point Parkway, Suite 99,
Alpharetta, GA 30022
www.auberins.com
E-mail: [email protected] Tel: 770-569-8420
Copyright 2007-2024, Auber Instruments All Rights Reserved.
No part of this manual shall be copied, reproduced, or transmitted in any way without
the prior, written consent of Auber Instruments. Auber Instruments retains the exclusive
rights to all information included in this document.
WWW.AUBERINS.COM
P7/7