Auber Instruments SYL-3615 Instruction Manual - Page 4

Browse online or download pdf Instruction Manual for Controller Auber Instruments SYL-3615. Auber Instruments SYL-3615 5 pages. Wi-fi bbq controller
Also for Auber Instruments SYL-3615: Instruction Manual (7 pages)

Auber Instruments SYL-3615 Instruction Manual
AUBER INSTRUMENTS
5. Accessing the menus
To access the menus, press and hold the SET key for 2 seconds.
5.1. Control Setting
Name
Description
Pit-AH
Pit High Alarm
Pit-AL
Pit Low Alarm
Food-AH
Food High Alarm
Probe3-
Probe 3 High Alarm
AH
Proportional
P
Constant
I
Integral Time
D
Derivative Time
T
Control Cycle Time
MODE
Control Mode
Save
Save PID Settings
Recall
Recall PID Settings
Back
Back to main menu
5.2. System Configuration
Name
Description
PRG
Multi-step program
OL
Open-lid detection
Detection
Minimum running
FMRV
voltage of the fan
OUTH
Output high-limit
OUTL
Output low-limit
C-F
Temperature unit
PB1
Probe 1 offset
PB2
Probe 2 offset
PB3
Probe 3 offset
Enable or disable the
Buzzer
on-board buzzer
nFIL
Powerline filter
LCD back-light
Brightness
brightness
Enable pushing
Push
temperature alarms to a
Alarm
paired mobile device
2020.11
Range
Initial
Note
0 ~ 999
350
1
0 ~ 999
50
2
0 ~ 999
350
3
0 ~ 999
350
3
1 ~ 999
45
4
0 ~ 9999
1200
5
0 ~ 999
75
6
2 ~ 200
15
7
Manual-FS,
Manual-TP,
PID-FS
8
PID-FS,
PID-TP
(Back), BGE,
WSM22,
Back
9
WSM18,
4,5,6
(Back), BGE,
WSM22,
Back
9
WSM18,
4,5,6
Range
Initial
On, off
Off
On, off
On
3.0 V ~ 11.0 V
4.0
0 ~ 100 (%)
100
0 ~ 100 (%)
0
° C, ° F
F
-99 ~ 100
0
-99 ~ 100
0
-99 ~ 100
0
On, Off
On
A, B, Auto
B
0 ~ 10
10
On, off
On
Enable pushing step
Push Step
notifications to a paired
mobile device
Restore all parameters
Reset
to factory default values
Reset
Reset Wi-Fi chip to AP
WiFi
mode (pairing mode)
Check and update
Update
device firmware
Back
Back to main menu
6. Using and mounting the controller
6.1. Operating temperature
The operating environment temperature for the meter is from 0° F ~
100° F (20° C ~ 50° C). The meter should be placed away from high heat
to protect the plastic housing and electronics. Mount or place the
controller away from the heat from the smoker. Avoid exposing the
controller under directly sunshine during hot summer days.
6.2. Protect the controller from rain
The case is not water-proof. If you want to use under light rain even for a
short period, it's better to cover the controller with a transparent and
waterproof bag or a container. Please also lift the controller from the
ground or any surface that may cause splashed water get into the case
from the bottom of the controller.
6.3. Mounting hooks
Two mounting hooks and two M4 screws are supplied with the controller.
These hooks can be installed as shown in Figure 9 and 10.
Note
10
11
12
13
14
15
15
15
Figure 9. How to install the mounting hooks to SYL-3615.
16
17
18
19
WWW.AUBERINS.COM
On, off
On
20
Yes, No
No
21
Yes, No
No
22
Yes, No
No
23