DAN DRYER FOAMTAP 382 User Manual - Page 6

Browse online or download pdf User Manual for Household Appliance DAN DRYER FOAMTAP 382. DAN DRYER FOAMTAP 382 9 pages.

TIMER SETTINGS

CALIBRATION OF SENSOR RANGE

Cut the power
Connect power to the dispenser
Place your flat hand close to the sensor until the green light on the front of the tap
turns off and starts flashing red.
Move your hand to the desired activation distance
The calibration setup has completed with the new distance when it starts blinking
green again.
10

TROUBLESHOOTING AND CORRECTIVE ACTIONS

SYMPTOM
CORRECTIVE ACTION
The dispenser has stopped
Ensure power is on.
dispensing
Ensure the soap reservoir is installed properly in it's
holder.
Ensure the hose is not bent or twisted.
Ensure the tubing is installed correctly and fits tightly. A
broken hose will not fit tightly on the pumpe, soap will
be dripping and it will eventually damage the control
box.
Ensure exit nozzle, hose and pump are not clogged.
Ensure that soap meets specified viscosity range:
SOAPTAP 378 viscosity 1cP - 3000cP.
FOAMTAP 382 viscosity 1cP.
Soap dispenser is malfunc-
Check the IR-sensor works properly (see section for
tioning
light indication p. 8).
Clean sensor for dirt.
Cut off power and reconnect to restart the system.
You could try to calibrate the sensor range (see section
for sensor calibration).
If the problem persists, replace the sensor.
The soap dispenser sounds
Ensure there are no bends, knots or kinks on the hose.
strained and it does not
Check if the nozzle, hose or pump is clogged.
dispense a full dose
Ensure that soap meets specified viscosity range:
SOAPTAP 378 viscosity: 1cP - 3000cP
FOAMTAP 382 viscosity: 1cP
Flashing green light
Confirm the unit's reservoir is filled with soap.
If soap reservoir is not empty, remove reservoir from
wall bracket and place it back to reset light indicator for
empty soap reservoir.
11