2.3
Hanger Installation
The 808HA plus can also be suspended with two hooks which are at the same height, the distance between two
hooks is adjustable.
Slide the hangers into the slot, make sure the distances between two hangers and the sides of the enclosure
are exactly the same so that the enclosure can be suspended horizontally. Use the screws and nuts in the
accessories bag to tighten the hanger.
2.4
Wire Connection
The 808HA Plus remote display provides two cord glands located on the side of the enclosure for cabling, one for
the power supply, one for serial communication.
The 808HA Plus provides RS-232 serial communications with weighing indicators. The serial communication
cord is pre-wired, the
red
wire is connected to RXD of the remote display,should be connected to TXD of the
indicator, the black wire is connected to GND of the remote display, should be connected to GND of the indicator.