Anyload A2A-D2 Product Manual - Page 3
Browse online or download pdf Product Manual for Amplifier Anyload A2A-D2. Anyload A2A-D2 8 pages. (v1611) load cell amplifier
1.
Introduction
Thank you for choosing Anyload A2A-D2 load cell amplifier. A2A strain gage
amplifier provides load cell and transducer signal conditioning. It is designed for
converting mV signal from load cell output into a 4~20mA or 0
A2A strain gage amplifier is a DC powered and can drive up to 4 x 350Ω load
cells or 8 X 700Ω load cells or 8 X 350Ω load cells or . It can be connected
directly to 1 or 2 load cells or to more than 2 load cells through a junction
box. The amplifier is equipped with individual adjustable resistors and has a
wide input signal of 0
manual here provides the installation, operation and calibration procedures of
the product.
2.
Installation
Preinstalled GORE breather vent with capacitive stainless steel screws:
Only simple tools like small size slotted screw driver and Philips screwdriver are
required for connecting cables during installation, adjusting the unit during
calibration and installation of enclosure cover.
3.
Specifications
Model
Max Power
Power Supply
Input Range
Output Signal
Working Temperature
Max Input Offset voltage
Min. Common Mode Ratio
(G=10)
Enclosure Material
2 |
ANYLOAD A2A-D2 Amplifier Product Manual (V1810)
±36mV and output signal of
W
V
mV
mA
V
°C (°F)
µV
dB
0
10V or 2 to 20mA. The
±
A2A-D2
4.35
24
0
±36
4-20
0
±10
-10 .... +50(14 .... 122)
50
100
Aluminum
10V signal. The
±