TROUBLE SHOOTING
SYMPTOMS
1. Gas leakage at the regulator
out let when the adjusting
screw is turned fully
counterclockwise.
2. With no fl ow through the
system (downstream valves
closed), outlet pres sure
increases steadily above the
set pres sure.
3. Gas leakage from spring case
or bonnet.
4. Excess drop in outlet pressure
with regulator fl ow open.
5. Gas leak age from any pipe
thread joint.
6. Gas leakage from relief valve.
7. Inconsistent repeat reading
8. Inlet or outlet pressure gauge
does not return to zero with
no pressure applied to the
regulator.
PROBABLE CAUSE
1. Seat leak or creep, have
regulator repaired.
2. Seat leak or creep, have
regulator repaired.
3. Diaphragm failure, have
regulator repaired.
4. Blockage in seat assembly
or inlet fi lter. Have regulator
repaired.
5. Loose fi tting, remove
connection clean, reapply
Tefl on tape and re tight en.
6. Possible faulty relief valve,
re place.
or creep, have re paired.
7. Seat sticking, have regulator
re paired. Possible bad
pressure gauge.
8. Gauge has suffered physical
dam age, replace gauge.
Possible seat leak
9