Figure 1. Connector Assembly
Press the silence button to turn off the buzzer.
10. Check the function of the alarm system by pressurizing the system and allowing the system to depres-
surize. When the cylinder is low (below the set point on the gauge), the green LED should turn off and
the red LED will illuminate. The buzzer will also sound. The buzzer may be silenced by pressing the
remote alarm's silence button.
OPERATION
The alarm is used to provide an audible and visual warning that a cylinder is nearly depleted.
alarm set point does not affect the operation of the system. No adjustment of the alarm set point during
normal operation should be necessary. If adjustment of the alarm set point is required, slide the red tab seen on
the inlet gauge to the desired alarm point (see figure 2).
If the green remote alarm LED's do not illuminate when the transformer is plugged in and the remote alarm is
not connected to the switchover, check the fuse. Disconnect the transformer from the power source. Remove
the four screws on the rear of the remote alarm. Remove the rear panel. Replace the fuse with the one indicated
on the label. Replace the rear cover and screws. Plug in the wall transformer. Check the remote alarm.
4
Adjusting the
Electrical Connection
Behind Pigtail
Alarm Set Point
Figure 2. Electrical connector and alarm setpoint location
Pressure Switch
Gauge
Electrical Connector
5