Addi-Data MSX-E1731 Quick Installation - Page 5

Browse online or download pdf Quick Installation for Data Loggers Addi-Data MSX-E1731. Addi-Data MSX-E1731 8 pages. Ethernet multifunction counter system

Examples:
Female connector 0 (n=0) –> Pin 2: (2 x 0 + 1) –> Digital I/O 1
Female connector 7 (n=7) –> Pin 2: (2 x 7 + 1) –> Digital I/O 15
EnDat 2.2 counter inputs
Pin-No.
connector,
8-pin, M12
Voltage supply
2, 8
24 V or 5 V
5, 1
3
4
7
6
5
–> Pin 4: (2 x 0) –> Digital I/O 0
–> Pin 4: (2 x 7) –> Digital I/O 14
Female
(can be set via jumper),
GND
A+
A-
B+
B-
Polarity
Output 5 V / 24 V
condition upon
delivery: 5 V
GND
Input RS422/TTL
Input RS422/TTL
Signal
Function
name
Supply for
EnDat 2.2
V+
encoder
GND
DATA_0+_x
Data line
DATA_0-_x
CLK_0+_x
Clock line
CLK_0-_x
www.addi-data.com