Duevi SIRPZ-RB-868 Operation
Browse online or download pdf Operation for Security Sensors Duevi SIRPZ-RB-868. Duevi SIRPZ-RB-868 2 pages. Battery powered indoor wireless siren
SIRPZ-RB-868 Battery powered indoor wireless siren
SIRPZ-RB-868 is an indoor wireless siren with high-power
piezoelectric horn, self-powered with batteries, used for
internal signaling of alarms, with indication of system arming
and disarming.
The siren is also equipped with a wired output which is
activated at the same time as the alarm sound.
PLEASE NOTE. Before definitively fixing the
siren, carry out some transmission tests towards
the control panel to check that the position is
adequate.
1. Identification of parts
A
Figure 1 – Identification of parts
A – Battery holder
1
2
3
Figure 2 – Scheda elettronica
1 – LED1
2 – Anti-removal tamper
3 – Settings Dip-switch
4 – Piezoelectric horn
2. Powering the siren
Insert 4 batteries in the battery holder A (Figure 1) and
connect the cable to the BAT connector (Figure 2 ref. 7).
ATTENTION - RESPECT THE POLARITY
B
B – Electronic board
4
5
6
7
8
5 – LED2
6 –JP1 jumper
7 – BAT connector
8 – Output terminals
SIRPZ-RB-868 21.09-M:2.0-H:2a-F:0.6+
3. Dip-switch
DIP
Function
1
Siren tone
(2000/2600 Hz)
2
Output logic
Active 2 sec at the
Control
3
Panel Model
4
Mode
Normal operation
PLEASE NOTE. The position of DIP3 (for the
selection of the panel model) is checked only
when the siren boot. In case of modification
disconnect the battery, wait a few minutes and
reconnect the battery.
4. Wireless enroll
To enroll the siren on the control panel (CE-LAN or EZY-
LAN), proceed as follows:
1.
Log in as INSTALLER on the control panel
2.
Enter SETUP> DEVICES> ADD NEW DEVICES. The
control unit waits for the sensor to be enrolled
3.
Enter ENROLL MODE on the siren (DIP4 = ON)
4.
Press the siren TAMPER button (Figure 2 ref. 2)
5.
Check that the control panel has learned the code
6.
Exit the ENROLL MODE on the siren (DIP4 = OFF)
5. Siren settings
Once the siren is enrolled, it is possible to set its sound
functions directly on the control panel setup.
Follow the control panel manual for details
6. Acoustic and visual signalling
Event
LED1
High Alarm (L2)
Low Alarm (L1)
Entering setup
Exiting setup
2 flashes
Arming
1 flash (*)
Disarming
3 flashes (*)
Continuous
Wireless enroll
flashing
(*) If enabled in the control panel configuration
OFF
ON
Tone 1
Tone 2
(3000/2600 Hz)
IMPULSIVE
ON/OFF
Active during the
start of alarm
alarm sound
CE-LAN
EZY-LAN
Wireless enroll
LED2
SIREN
High intensity
on
Sound
Low intensity
Sound (*)
5 beeps
2 beeps
1 beep (*)
3 beeps (*)