I
NSTALLATION
5
Flush supply hoses
A
Connect supply hoses to supply
terminals and connect together using
a union fitting as shown.
B
Operate auxiliary valve for 30 sec.
C
Remove union fitting
6
Install hoses
CAUTION: Allow for 100 mm movement
in each direction for sideshifting ('rolling'
hose arrangement recommended).
7
Remove fork locking pins
FP1115.eps
6055911-R8 EN
WARNING: Remove locking pins
from forks. Make sure that forks
slide freely on carriage bars.
Sideshift
CLOSE
Right
Forks
Back (Driver's) View
Remove Fork
Pin Assembly
FP0726.eps
OPEN
Sideshift
Forks
Left
FP0701.eps
FP1432.eps
9