T
RUCK REQUIREMENTS
Truck Relief Setting
2300 psi (160 bar) Recommended
2600 psi (180 bar) Maximum
Truck Flow Volume
Fork Position
Sideshift
➀ Cascade A-Series Fork Positioner/Sideshifters are compatible with
SAE 10W petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-
5606 or MIL-0-2104B. Use of synthetic or aqueous base hydraulic
fluid is not recommended. If fire resistant hydraulic fluid is required,
special seals must be used. Contact Cascade.
➁ Flow less than recommended will result in slow fork positioning speed.
➂ Flow greater than maximum can result in excessive heating, reduced
system performance and short hydraulic system life.
Carriage Mount Dimension (A)
A
Class II
Class III 18.68 in. (474.5 mm)
Class IV 23.44 in. (595.5 mm)
GA0028.eps
Auxiliary Valve Functions
Check for compliance with
ANSI (ISO) standards:
GA0082.eps
1849482-R2
➀
Min.
➁
Recommended Max.
3 GPM
4 GPM
(11 L/min.)
(15 L/min.)
1 GPM
2 GPM
(4 L/min.)
(7.5L/min.)
Minimum
14.94 in. (380.0 mm)
15.00 in. (381.0 mm)
18.74 in. (476.0 mm)
23.50 in. (597.0 mm)
Sideshift
Tilt
Left
Forward
Hoist Down
Hoist Up
Tilt
Sideshift
Back
Right
➂
5 GPM
(19 L/min.)
3 GPM
(12 L/min.)
ITA (ISO)
Maximum
Carriage –
bars. Make sure that bars are parallel and that
ends are flush. Grind smooth any protruding
welds that may affect Sideshifter lower
bearings. Repair any damaged notches.
Open
Forks
Close
Forks
GA0131.eps
Clean and inspect carriage