Dukane iQ LS Application Note - Page 4

Browse online or download pdf Application Note for Power Supply Dukane iQ LS. Dukane iQ LS 16 pages. Ultrasonic probe system, automation interface guidelines

DUKANE
Intelligent Assembly Solutions
All System Inputs are optically isolated from the internal circuits and can be connected to sinking or sourcing PLC output
cards. The inputs will draw approximately 10mA with a 24Vdc supply. The Systems Inputs can also be configured for a
contact closure if necessary.
PLC Output Card
Contact closure or
transistor output
Notes:
1. All System Inputs share the same Isolated Common (J2-13). It is critical that the isolated common is connected
to the positive supply or ground.
2. J2-1 can be used in place of the 24Vdc supply. If so, J2-13 must be connected to J2-2.
Warning: Any connection to the Ultrasound Activation/Cycle Start Input (J2-8) or the Automation Thruster Control Input
(J2-9) should be disabled during an emergency stop condition.
AN502 (REV 07)
Page 4 of 16
Connecting System Inputs
PLC Sourcing Output Card
+24Vdc Supply
(+30Vdc max)
PLC Digital Outputs
iQ Digital Input
Sourcing Current
Sinking Current
Isolated Common
APPLICATION NOTE
iQ System Inputs
J2-13
0Vdc Return
AN502
© Dukane 2016. All Rights Reserved.