Dukane iQ LS-E Application Note - Page 5

Browse online or download pdf Application Note for Power Supply Dukane iQ LS-E. Dukane iQ LS-E 16 pages. Ultrasonic probe system, automation interface guidelines

DUKANE
Intelligent Assembly Solutions
PLC Output Card
Contact closure or
transistor output
Notes:
1. All System Inputs share the same Isolated Common (J2-13). It is critical that the isolated common is connected
to the positive supply or ground.
2. J2-1 can be used in place of the 24Vdc supply. If so, J2-13 must be connected to J2-1 and 0Vdc to J2-2.
Warning: Any connection to the Ultrasound Activation/Cycle Start Input (J2-8) or the Automation Thruster Control Input
(J2-9) should be disabled during an emergency stop condition.
AN502 (REV 07)
Page 5 of 16
Connecting a PLC Sinking Output Card
PLC Digital Outputs
Sinking Current
0Vdc Return
APPLICATION NOTE
iQ System Inputs
+24Vdc Supply
(+30Vdc max)
Isolated Common
J2-13
iQ Digital Input
Sourcing Current
AN502
© Dukane 2016. All Rights Reserved.