Dunavox DAUF-9.22SS Instruction Manual - Page 11

Browse online or download pdf Instruction Manual for Wine Cooler Dunavox DAUF-9.22SS. Dunavox DAUF-9.22SS 13 pages.

Appliance is not
cold enough.
Appliance turns
itself on and off
frequently.
The light does not
work.
Vibrations.
The appliance
seems to make too
much noise.
The door will not
close properly.
Error code of single
zone model
Error code of dual
zone model
The temperature is not set correctly.
The ambient temperature could require a
higher temperature setting.
The door was opened too often.
The door was not closed completely. Door is
not hermetically-sealed.
The condenser is too dirty.
The ventilation opening is blocked or too
dusty.
The room temperature is higher than
average.
A large amount of bottles has been added to
the unit.
The door is open too often.
The door is not closed completely.
The door gasket does not seal properly.
Appliance is not connected to a power
supply.
The circuit breaker tripped or a blown fuse.
The light was switched off on the control
panel.
The appliance is not properly level.
The rattling noise may come from the flow of the refrigerant, which is normal. As each
cycle ends, you may hear gurgling sounds caused by the flow of refrigerant in your
appliance.If temperature fluctuations occur, the contraction and expansion of the inner
walls may cause popping and cracking noises.
The appliance is not properly level.
The appliance is not properly level.
The door was reversed and not properly
installed.
The gasket is dirty.
The shelves are out of position.
E1: Temp sensor open circuit
E2: Temp sensor short circuit
E3: Evaporator sensor open circuit
E4: Evaporator sensor short circuit
"88" indicates that the connection wire of
control board is failed.
E1: Upper zone Temp sensor open circuit
E2: Upper zone Temp sensor short circuit
E3: upper zone Evaporator sensor open
circuit
E4:upper zone Evaporator sensor short
circuit
E5: Lower zone Temp sensor open circuit
E6: Lower zone Temp sensor short circuit
"88" indicates that the connection wire of
control board is failed.
Check the set temperature.
a higher temperature.
Do not open the door more often
than necessary.
Close door properly.
Check the door seal and clean or
replace.
Clean the condenser when
necessary.
Clear the obstructions and clean
the dust.
Put the appliance in a cooler
place.
Leave the appliance to work for a
while until the set temperature
has been reached.
Do not open the door more often
than necessary.
Close door properly.
Check the door seal and clean or
replace.
Connect the appliance.
Switch on circuit breaker or
replace fuse.
Switch on the light.
Level the appliance with the
adjustable feet.
Level the appliance with the
adjustable feet.
Level the appliance with the
adjustable feet.
Check the door hinge and
reassemble correctly.
Clean the door gasket.
Check the shelves and refit
correctly.
Check the temp sensor.
Check the temp sensor.
Check the evaporator sensor.
Check the evaporator sensor.
Check the connection wire of
control board.
Check the upper temp sensor.
Check the upper temp sensor.
Check the evaporator sensor.
Check the evaporator sensor.
Check the lower temp sensor.
Check the lower temp sensor.
Check the connection wire of
control board.
Set