Pull idler gear to 'out' position.
The metering shaft will rotate
at half speed for smoother
Yes
delivery at low rates. Look up
revised rates on 'Increased
Accuracy' chart for normal
sized seed.
'Enviro DD30'
Start
Empty boxes and clear old
seed and fertilizer from
metering unit.
Is seed size
between 4 and
10mm?
Yes
Locate product in 'Normal'
seed table.
Look up 'Setting Postion' for
desired output.
Is Setting Position
25mm or less?
No
Ensure that idler gear is
pushed in and not meshing to
the external gear. The
metering shaft will rotate at
high speed when seeding.
Ensure that the normal/fine
toggle is not engaged with the
hex shaft and that the end is
pointing toward the metering
housing.
Turn handle on the metering
housing to the desired 'Setting
Position' for the chosen
product from the table.
Perform Calibration -
refer to next page.
Pre-Calibration Setup
normal/fine toggle
No
Locate product in 'Fine' seed
table.
Look up 'Setting Postion' and
'Rate' for desired output.
Does 'Rate' in
table specify
'low'?
No
Ensure that idler gear is
pushed in and not meshing to
the external gear. The
metering shaft will rotate at
high speed when seeding.
Ensure that the normal/fine
toggle is engaged with the hex
shaft. You will need to turn the
the metering handle so the
scale reads zero and engage
the toggle with the cutout in the
hex shaft.
Turn handle on the metering
housing to the desired 'Setting
Position' for the chosen
product from the table.
Perform Calibration -
refer to next page.
7
high (idler in)
low (idler out)
Yes
Pull idler gear to 'out' position.
The metering shaft will rotate
at half speed.
Only switch from
normal to fine seed
if the seed hopper is
empty
Pt. No. 67453
Issue 0321