Danfoss VLT HVAC Drive FC 102 Operating Instructions Manual - Page 5

Browse online or download pdf Operating Instructions Manual for DC Drives Danfoss VLT HVAC Drive FC 102. Danfoss VLT HVAC Drive FC 102 16 pages. Igbt module replacement for d1h–d8h drives
Also for Danfoss VLT HVAC Drive FC 102: Operating Manual (16 pages), Installation Manual (20 pages), Installation Instructions Manual (6 pages), Installation Instructions Manual (12 pages), Installation Manual (18 pages), Installation Instructions Manual (11 pages), Installation Instructions Manual (8 pages), Installation Instructions Manual (10 pages), Installation Manual (6 pages), Installation Instructions Manual (6 pages), Installation Manual (16 pages), Installation Manual (8 pages), Instruction Manual (16 pages), Installation Instructions Manual (6 pages), Installation Manual (6 pages)

Danfoss VLT HVAC Drive FC 102 Operating Instructions Manual
Introduction

1.4 Approvals and Certifications

Table 1.2 Approvals and Certifications
More approvals and certifications are available. Contact
local Danfoss partner.
Applied standards and compliance
Use of Safe Torque Off on terminal 37 requires that the
user satisfies all provisions for safety including relevant
laws, regulations and guidelines. The integrated STO
function complies with the following standards:
IEC 60204-1: 2005 Stop category 0 – uncontrolled
stop
EN 60204-1: 2006 Stop category 0 – uncontrolled
stop
IEC/EN 61508: 2010 SIL2
IEC/EN 61800-5-2:2007
IEC/EN 62061: 2005 SIL CL2
ISO 13849-1: 2006 Category 3 PL d
EN ISO 13849-1:2008 Category 3 PL d
®
VLT
Frequency Converters - Safe Torque Off Operating Instructions
MG37D102 - Rev. 2013-11-15