Danfoss 3020P Installation & User's Instructions - Page 4
Browse online or download pdf Installation & User's Instructions for Thermostat Danfoss 3020P. Danfoss 3020P 12 pages. Electro-mechanical 24 hour timeswitch with auxiliary heating switch
Installation
1. Unscrew fixings rings from selector switches, move all
four tappets to top of dial and remove outer case.
2. Slacken the two screws securing the plug-in module
to backplate and separate module from backplate by
pulling upwards.
3. Fix backplate to wall (3 hole fixing).
4. Referring to wiring diagrams on pages 5 and 6 make
electrical connections as shown (as applicable).
5. Secure cables under cable clamp.
6. Ensure all dust and debris has been cleared away
from the area then plug in timeswitch module and re-
tighten the 2 retaining screws - do not overtighten.
7. Remove cut out from bottom of outer case as required.
Refit outer case and selector switch fixing rings.
Check that outer case sits squarely on body and is not
distorted by an uneven wall surface.
8. Rotate dial clockwise through at least one complete
revolution and check that all four tappets are clear of
outer case aperture.
9. Switch on mains, turn main selector switch to 'ON' and
light boiler according to manufacturer's instructions.
Operate Heating Switch to check pump/fan.
10. Turn main selector switch to 'TIMED' and rotate dial
clockwise manually through at least one complete
revolution to check that each tappet strikes the index
wheel cleanly and operates the boiler/pump correctly
according to the times set on the dial.
4