The thermostat has a button to adjust the temperature
setting with a scale from -10 °C to +50 °C . An LED indicator
shows standby periods (green light) and heating periods
(red light).
More information on this product can also be found at:
ectemp�danfoss�com
1�1
Technical Specifications
Operation voltage
Standby power consumption
Relay:
Resistive load
Inductive load
Sensing units
Sensing values:
0°C
25°C
50°C
Hysteresis
Ambient temperature
Lowering in economy periods
Temperature range
Minimum temperature range
Cable specification max
4
Danfoss ECtemp 316
220-240 V~, 50 Hz
Max 0.25 W
Max 16 A / 3680 W @ 230 V
cos φ= 0.3 max 1 A
NTC 15kOhm at 25 °C
42 kOhm
15kOhm
6 kOhm
0 to 6 °C
10 °C to +45 °C
0 to 8 °C
-10 °C to +50 °C
-10 °C to +5 °C
1x4 mm2 or 2x2,5 mm2
Installation Guide