Danfoss TP7000-RF Installation Instructions Manual - Page 3

Browse online or download pdf Installation Instructions Manual for Thermostat Danfoss TP7000-RF. Danfoss TP7000-RF 9 pages. Electronic programmable room thermostat
Also for Danfoss TP7000-RF: Installation Instructions User Instructions (14 pages)

Danfoss TP7000-RF Installation Instructions Manual
Po Polsku Specyfikacja
Ważna uwaga RF: Należy sprawdzić, aby w
prostej linii między termostatem i nadajnikiem
nie znajdowały się duże metalowe przedmioty,
takie jak bojlery lub inne duże urządzenia,
gdyż mogą one uniemożliwić łączność między
termostatem i nadajnikiem.
(GB) Mounting / (F) Montage / (DK) Montering / (ES) Montaje / (D) Befestigung / (NL) Montage / (PL) Zamocowanie
(GB) Wiring (hard-wired versions only) / (F) Câblage (versions câblées uniquement) / (DK) Ledningsføring (ledningstrukne
versioner) / (ES) Cableado (solo versiones de conexión permanente / (D) Verkabelung (nur bei Kabelversion) / (NL) Bedrading (alleen
uitvoeringen met kabelaansluiting) / (PL) Podłączanie przewodów (tylko dla wersji podłączanych na stałe)
(GB) Connections / (F) Connexions / (DK) Opkoblinger / (ES) Conexiones / (D) Anschlüsse / (NL) Aansluitingen (PL)
ELECTRONICS
1
2
3
4
5
LOAD
REMOTE
START-UP
'B' models
only
TP7000
Thermostat Features
Order code - Built-in sensor model
- Remote sensor model, (A models)
Control type - On/Off or chrono- proportional, 3/6
cycles per hour
Control type - On/Off or chrono- proportional, 6/12
cycles per hour, (C models)
RF - wireless thermostat
Hardwired thermostat
Digital clock type
Selectable 7-day or 5/2-day operation
Number of events per day
Control temperature range
Total switching differential (On/off mode)
Factory pre-set programme
Programmable holiday mode
Installer selectable Optimum start control
Themostat mode and frost mode
Power supply
Memory backup
Switching action of output relay
Switch rating of relay contact, voltage and current
Transmitter frequency (RF models only)
Transmitter range (RF models only)
Dimensions (mm)
Pollution Situation
Rated Impulse Voltage
Ball Pressure Test
Note 1): Unit must powered up for 6 days to charge cell before full back-up is available
6
7
L
N
230Vac
REMOTE
SENSOR
'A' models
only
TP7000-RF
087N741000
087N741400
087N741100
087N741500
l
l
l
Off, 5 - 30°C, (can be set to Fahrenheit by user)
Yes - Off, 30, 60, 90 or 120 minutes early switch on at set-point minus 4K
Yes, set to 1.0°C, but adjustable between 5 - 30°C
2 x AA/MN1500/LR6 alkaline batteries
Capacitor during battery change for I minute
N/A
N/A
433.92 MHz
30 meters max.
N/A
ELECTRONICS
1
2
3
4
5
6
LOAD
REMOTE
REMOTE
SENSOR
START-UP
'B' models
'A' models
only
TP7000M
TP7000
087N740000
087N740400
087N740800
087N740100
087N740500
087N740900
l
l
l
24 hour, (can set to AM/PM mode by user)
Yes
Up to 6
<1.0°C
Yes
Yes, up to 99 days
Rechargable cell
SPST
3(1) A, 230 volts
N/A
N/A
138 wide x 88 high x 28 deep
Degree 2
2.5Kv
75°C
7
2
3
1
only
TP7000-RF
TP7000M
087N741900
087N742000
l
l
l
230v, 50 Hz
(see note 1)
ELECTRONICS
4
5
6
7
REMOTE
SENSOR
'A' models
only
3