Also for Danfoss VLT HVAC Drive FC 102: Operating Manual (16 pages), Installation Manual (20 pages), Installation Instructions Manual (6 pages), Installation Instructions Manual (12 pages), Installation Manual (18 pages), Installation Instructions Manual (11 pages), Installation Instructions Manual (8 pages), Installation Instructions Manual (10 pages), Installation Manual (6 pages), Operating Instructions Manual (16 pages), Installation Manual (16 pages), Installation Manual (8 pages), Instruction Manual (16 pages), Installation Instructions Manual (6 pages), Installation Manual (6 pages)

Danfoss VLT HVAC Drive FC 102 Installation Instructions Manual
Installation Instructions

1.3 Voltage Ratings

FC 102/FC 202
[V]
[HP]
208-230
1.5-5
460-480
1.5-10
575-600
1.5-10
Table 1.7 Frames A1 - A3
FC 102/FC 202
[V]
[HP]
208-230
7.5-15
460-480
15-25
575-600
15-25
Table 1.8 Frame B1
FC 102/FC 202
[V]
[HP]
208-230
20
460-480
30-40
575-600
30-40
Table 1.9 Frame B2

1.4 Fuse Replacement Table

Drive Rating
[HP]
[kW]
208-230 V
0.5
0.37
n/a
0.75
0.55
n/a
1
0.75
n/a
1.5
1.1
LP-CC-10 10 A,
600 V, Class CC
2
1.5
LP-CC-15 15 A,
600 V, Class CC
3
2.2
LP-CC-20 20 A,
600 V, Class CC
4
3
LP-CC-25 25 A,
600 V, Class CC
5
3.7/4
LP-CC-30 30 A,
600 V, Class CC
7.5
5.5
JJN-50 50 A, 300 V,
Class T
10
7.5
JJN-50 50 A, 300 V,
Class T
15
11
JJN-60 60 A, 300 V,
Class T
20
15
JJN-80 80 A, 300 V,
Class T
25
18.5
JJN-125 125 A,
300 V, Class T
4
VLT® FC Series Internal Fuse Replacement
FC 302
[HP: NO]
[HP: HO]
1/4-5
1/2-10
1-10
FC 302
[HP: NO]
[HP: HO]
10-15
7.5-10
20-25
15-20
15-25
15-20
FC 302
[HP: NO]
[HP: HO]
20
15
30-40
25-30
30-40
25-30
FC 102/FC 202
460-480 V
575-600 V
n/a
n/a
n/a
LP-CC-6 6 A, 600 V,
LP-CC-5 5 A, 600 V,
Class CC
LP-CC-10 10 A,
LP-CC-10 10 A,
600 V, Class CC
600 V, Class CC
LP-CC-10 10 A,
LP-CC-10 10 A,
600 V, Class CC
600 V, Class CC
LP-CC-15 15 A,
LP-CC-15 15 A,
600 V, Class CC
600 V, Class CC
LP-CC-20 20 A,
LP-CC-20 20 A,
600 V, Class CC
600 V, Class CC
LP-CC-25 25 A,
LP-CC-25 25 A,
600 V, Class CC
600 V, Class CC
LP-CC-30 30 A,
LP-CC-30 30 A,
600 V, Class CC
600 V, Class CC
JJS-40 40 A, 600 V,
JJS-35 35 A, 600 V,
Class T
JJS-40 40 A, 600 V,
JJS-35 35 A, 600 V,
Class T
JJS-50 50 A, 600 V,
JJS-45 45 A, 600 V,
Class T
®
MI92D102 - VLT
is a registered Danfoss trademark
FC 102/FC 202
[V]
[HP]
208-230
25-30
460-480
50-75
575-600
50-75
Table 1.10 Frame C1
FC 102/FC 202
[V]
[HP]
208-230
40-60
460-480
100-125
575-600
100-125
Table 1.11 Frame C2
208-230 V
n/a
LP-CC-5 5 A, 600 V,
Class CC
n/a
LP-CC-10 10 A,
600 V, Class CC
n/a
LP-CC-10 10 A,
600 V, Class CC
LP-CC-10 10 A,
Class CC
600 V, Class CC
LP-CC-15 15 A,
600 V, Class CC
LP-CC-20 20 A,
600 V, Class CC
LP-CC-25 25 A,
600 V, Class CC
LP-CC-30 30 A,
600 V, Class CC
LP-CC-50 50 A,
600 V, Class CC
JJN-60 60 A, 300 V,
Class T
JJN-80 80 A, 300 V,
Class T
Class T
JJN-125 125 A,
Class T
300 V, Class T
JJN-125 125 A,
Class T
300 V, Class T
FC 302
[HP: NO]
[HP: HO]
25-30
20-25
50-75
40-60
50-75
40-60
FC 302
[HP: NO]
[HP: HO]
40-60
30-50
100-125
75-100
100-125
75-100
FC 302
460-480 V
575-600 V
LP-CC-6 6 A,
n/a
600 V, Class CC
LP-CC-6 6 A,
n/a
600 V, Class CC
LP-CC-6 6 A,
LP-CC-5 5 A, 600 V,
600 V, Class CC
Class CC
LP-CC-6 6 A,
LP-CC-5 5 A, 600 V,
600 V, Class CC
Class CC
LP-CC-10 10 A,
LP-CC-10 10 A,
600 V, Class CC
600 V, Class CC
LP-CC-10 10 A,
LP-CC-10 10 A,
600 V, Class CC
600 V, Class CC
LP-CC-15 15 A,
LP-CC-15 15 A,
600 V, Class CC
600 V, Class CC
LP-CC-20 20 A,
LP-CC-20 20 A,
600 V, Class CC
600 V, Class CC
LP-CC-25 25 A,
LP-CC-25 25 A,
600 V, Class CC
600 V, Class CC
LP-CC-30 30 A,
LP-CC-30 30 A,
600 V, Class CC
600 V, Class CC
JJS-40 40 A, 600 V,
JJS-35 35 A, 600 V,
Class T
Class T
JJS-50 50 A, 600 V,
JJS-45 45 A, 600 V,
Class T
Class T
JJS-60 60 A, 600 V,
JJS-50 50 A, 600 V,
Class T
Class T