Danfoss APP 16-22 Disassembling And Assembling Instructions - Page 3

Browse online or download pdf Disassembling And Assembling Instructions for Water Pump Danfoss APP 16-22. Danfoss APP 16-22 18 pages. Changing pistons
Also for Danfoss APP 16-22: Instruction Manual (8 pages)

Danfoss APP 16-22 Disassembling And Assembling Instructions
Instruction
1.

Disassembling

2.
Disassembling the
pump
Disassembling and assembling APP 11-13 and APP 16-22
Important: It is essential that the pump is
serviced in conditions of absolute cleanliness.
Place the pump on a pallet or other stable
surface above the ground. Ensure that the pump
cannot roll. It must be possible to place the
pump vertically with the shaft pointing down-
wards. This can be done between two pallets or
between two boards on a pallet provided that
the distance to the ground is minimum 100 mm.
(3,94 inches). See example page 4 item 7.
1.
Disconnect the pump from the rest of the
system.
2.
Using the 10 mm combination wrench,
unscrew the four bolts from shaft seal
flange. If shaft seal flange is stuck, place
two bolts in threaded holes in shaft seal
flange to remove it.
180R9228 / 521B1181 / DKCFN.PI.013.A2.02 / 10.2013
For a better understanding of the pump, please
see exploded views on page 15 to 17.
WARNING:
Do not reuse disassembled O-rings or shaft
seal as they might be damaged. Always use
new O-rings.
3.
Remove ceramic ring from flange by
carefully pushing it from the back of the
sealing ring.
3