Danfoss APP 3.5 Instruction Manual - Page 6
Browse online or download pdf Instruction Manual for Water Pump Danfoss APP 3.5. Danfoss APP 3.5 8 pages. Changing shaft seal
Also for Danfoss APP 3.5: Disassembling And Assembling Instructions (12 pages), Manual (5 pages)
Instruction
6
APP pump instruction APP 0.6-1.0, APP 1.5-2.5 and APP 3.0-3.5
3.3 Orientation
The pump can be mounted/oriented in any
horizontal direction. Vertically only with the shaft
pointing upwards.
3.4 Protection from too high pressures
The pump should be protected against too high
pressure by means of a pressure relief valve or a
bypass/unloading valve placed on the pressure
side.
3.5 Connections
APP 0.6-1.0
P
Thread size
G 1/2 × 15
Max tighten
25 Nm
torque
18 (lbf ft)
Recommended torque values refer to steel washers containing a rubber sealing element.
180R9065 / 521B0733 / DKCFN.PI.013.C4.2T / 09.2012
The valve should be placed as close to the pump
as possible. The opening characteristics of the
valve must not result in peak pressures higher
than 200 bar (2900 psi).
The valve outlet must not be connected
directly to the pump suction line. It shall be
connected directly to the tank.
T
C
G 1/2 × 15
M6 Hexagon
NV 4
25 Nm
5 Nm
18 (lbf ft)
3.5 (lbf ft)
P
Pressure
T
Tank
C
Bleeding
D
Parallel key 5 × 5 × 20,
DIN 6885
APP 1.5-2.5 and APP 3.0-3.5
P
T
G 1/2 × 15
G 3/4 × 17
25 Nm
25 Nm
18 (lbf ft)
18 (lbf ft)
C
G 1/4, NV 6
14 deep
15 Nm
11 (lbf ft)