Danfoss PAH 12.5 PAHT 10 Disassembling And Assembling - Page 3

Browse online or download pdf Disassembling And Assembling for Water Pump Danfoss PAH 12.5 PAHT 10. Danfoss PAH 12.5 PAHT 10 20 pages.

Danfoss PAH 12.5  PAHT 10 Disassembling And Assembling
Instruction
1.

Disassembling

Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
1.
Tools required for dismantling.
3.
Dismantle the front cover using a vice.
5.
Remove the two small O-rings from the
flange. Remove the seal from the front
cover using a screwdriver.
180R9095 / 521B0986 / DKCFN.PI.010.NA3.02 / 09.2013
2.
Remove the parallel key and unscrew the
front cover.
4.
Remove the shaft seal using two screw-
drivers.
6.
Unscrew the four screws for the housing.
3