12
Disassembling and assembling PAH 10-12.5, PAHT 10-12.5 and PAHT G 10-12.5
11.
Mount the retainer guide on the spring
guide.
13.
Insert the pistons.
15.
Place pin and place swash plate fittet on
guide pin and center hole.
180R9095 / 521B0986 / DKCFN.PI.010.NA3.02 / 09.2013
12.
Mount the retainer plate on the retainer
guide. Ensure that the bended surface
points downwards.
14.
All pistons inserted.