12
15. Place pin and place swash plate fittet on
guide pin and center hole.
16. Place the screw in the center hole.
Alignment
hole
Guide pin
18. Mount the pump housing using the pin as
guide.
180R9095 | 521B0986 0 | DKCFN.PI.010.NA4.02| 06.2017
17. Tighten to a torque of 10 ±1 Nm.
19. Press the housing down by hand and
insert the screws.