Apollo Smart features
1 LCD Display
11 Error code information
2 MODE key
12 Power/data cable
3 DOWN key
13 Manufacturing information
4 ENTER key
14 Location feature (see STEP 3 of the installation guide)
5 UP Key
15 USB connector
6 SETUP Key
16 Mains power plug
7 Alarm Red LED
17 Apollo Smart Transmitter
8 Wall mount feature
18 Self-tapping screws x 2
9 Beeper aperture
19 Weather seal (Gasket)
10 RESET access (pressing reset
20 Apollo Smart Transmitter oil level display
erases all historical data.
Apollo Smart Key Functions
MODE
When in NORMAL mode press MODE to move between the current and the historical information screens.
r
Press UP to move between screens when in NORMAL mode.
Use it to increase a setting when in SETUP mode.
The ENTER key is used only in SETUP mode. It is used to save the setting shown on the display and then move
ENTER
automatically to the next SETUP number.
s
Press DOWN to move between screens when in NORMAL mode.
Use it to decrease a setting when in SETUP mode.
SETUP
Press SETUP for 3 seconds to enter SETUP. When in SETUP, press SETUP to exit from SETUP mode.
s r
When in NORMAL mode, by pressing together and releasing, the screen will flash the current tank
+
configuration for 20 seconds. Press any key to return to NORMAL mode.
LED
The red light above the ENTER key flashes when there is an Alarm condition (see section 6) and on
receiving an RF signal from the Apollo Smart Transmitter
DISPLAY - SYMBOLS & INDICATORS
The Apollo Smart contains a display that conveys a variety of information during
normal use and during its initial setup and configuration for use with your oil
tank. The display contains three sections (1, 2, & 3) as indicated:
16
20
17
13
18
19
15
14
1
- Used for SETUP and displays SETUP number, and in normal use displays room temperature.
2
-
Tank information including a visual bar-graph of the oil level in the tank.
3
-
Information about the remaining usable oil in litres or as a %, the 'Days to Empty', and the average
and cumulative use of oil in litres, cost and KgCO
Apollo Smart Monitor and Transmitter Display Symbol reference
TANK TYPE
Indicates the Tank Type being selected
A, B, C
A, B, C are types of tank shapes (see diagrams in section 5)
ROOM TEMPERATURE The value displayed is the Room Temperature
20
Numeric display - Shows the Room Temperature in normal mode e.g 20.
3
Shows the Setup mode number when in setup mode, e.g. SETUP mode 3
1
°C
The value displayed is temperature in degrees Celcius
cm
The value displayed is in centimetres
SETUP
Setup mode is active
H
The value displayed is the tank height
W
The value displayed is the tank width
Apollo Smart Monitor Display:
Bargraph indicator of liquid level - each bar represents 10% of tank height
Apollo Smart Transmitter Display:
Tanks 1m in height or greater - each bar represents 1/10th of the top meter of the tank.
Tanks less than 1m in height - each bar represents 1/10th of a metre
FULL
Indicates the 'Full' level of the bargraph indicator
LIQUID LEVEL
Indicates the bargraph is showing the liquid level
EMPTY
Indicates the 'Empty' level of the bargraph indicator
2
When flashing there has been a leak into the 'Bund' (double skinned tanks).
BUND ALARM
The 10 bars and the RED LED will also be flashing at the same time.
TANK LOW BATTERY The Apollo Smart Transmitter battery needs to be changed.
Flashing - The remaining liquid level in the tank is at 10% or below of tank height.
(Appears on both the Apollo Smart Monitor and Transmitter)
Flashing - There is a problem with the RF signal from the Apollo Smart Transmitter.
(Appears on both the Apollo Smart Monitor and Transmitter)
The temperature is close to or below the limit of operation of the Apollo Smart
Transmitter - the information accuracy may be affected.
£
The value displayed is in Sterling pounds
The value displayed is in Euro
The value displayed is the % of usable oil remaining in the tank.
%
67 5
Numeric display - used to show numeric values and the time.
- - -
A numeric value is not available to be displayed when '---' is shown.
KgCO
The value displayed is of Kg of CO
2
cm
The value displayed is in centimetres
3
Ltr.
The value displayed is in Litres
/ (Ltr.)
The value displayed is per (litre)
USB data activity.
AVERAGE PER DAY
The value displayed is the average per day based on the last 7 days usage
AVERAGE PER WEEK The value displayed is the average per week based on the last 14 days usage
The value displayed is the estimated number of days of oil remaining in the tank. It is
DAYS TO EMPTY
computed by dividing the volume of usable oil left in the tank by the current daily
average use.
LAST 30 DAYS
The value displayed is the estimated usage over the last 30 days
LAST 365 DAYS
The value displayed is the estimated usage over the last 365 days
9-5565-01
. Time is also displayed here.
2
(carbon emissions)
2